individuals; therefore, discuss such issues with your doctor or diabetes team in advance. 

 

Consuming carbohydrates may cause rebound hyperglycemia, especially when you eat 

too much; pay attention to the change in the blood glucose level afterwards. As there 

can be a delay in the rise in sensor glucose levels, confirm the blood glucose level by 

fingertip blood sampling if necessary. Remember that the changes in the sensor glucose 

levels  are  approximately  5  to  10  minutes  delayed  compared  with  the  actual  blood 

glucose levels.   

 