About Glucose Alarms
Example of a High Glucose Threshold Alarm -
The alarm sounds
when
the glucose level crosses
the preset threshold value.
In addition to alerting you of a high or low glucose condition, the system can also alert you
before
you reach such a high or low glucose condition. These alarms are called the projected
high and projected low glucose alarms. They can be set at low, medium and high sensitivities
to alert you approximately 10, 20 or 30 minutes before your glucose levels reach the high or
low threshold values, assuming your glucose keeps changing at the same rate. You can turn all
glucose alarms ON or OFF. If the alarms are turned OFF, you will not get any alarms.
These alarms are designed to help you take action as
soon as you are notified. Projected low and projected
high glucose alarms increase the overall ability to
detect a condition of low or high glucose. However,
they cannot be relied on exclusively for notification of
all low and high glucose conditions.
High and low glucose threshold alarms can detect
a low or high glucose condition more often than
projected high and projected low glucose alarms (see
alarm performance under performance characteristics
for more information). Therefore, do
NOT
turn off the
low and high glucose threshold alarms to rely just on
the projected high and projected low glucose alarms.
In order to get maximum notification of low and high
glucose conditions, use both the low and high glucose
threshold alarms
AND
the projected low and projected
high glucose alarms.
Example of a Low Glucose Threshold Alarm -
The alarm sounds
when
the glucose level crosses
the preset threshold value.
Example of a Projected High Glucose Alarm - The
alarm sounds
before
the glucose level reaches the
preset threshold value.
Example of a Projected Low Glucose Alarm - The
alarm sounds
before
the glucose level reaches the
preset threshold value.
The FreeStyle Navigator® system is designed to alert you when your glucose levels reach preset
low or high values. These values or ‘threshold values’ can be programmed in the receiver for
any individual. These high and low glucose alarms or the threshold alarms are designed to
alert you
when
your glucose levels cross these threshold values.
Customer Care: 1-866-597-5520
68
Section 8
Set, Review, or Change the Alarm Settings
High Threshold
(180 mg/dL)
Low Threshold
(80 mg/dL)
High Threshold
(180 mg/dL)
Low Threshold
(80 mg/dL)
Summary of Contents for FreeStyle Navigator
Page 2: ......
Page 4: ......
Page 8: ......
Page 9: ...1 Getting Acquainted ...
Page 23: ...2 Install or Replace Transmitter and Receiver Batteries ...
Page 29: ...3 Set the Time and Date ...
Page 34: ...Customer Care 1 866 597 5520 ...
Page 35: ...4 Perform a Control Solution Test ...
Page 42: ...Customer Care 1 866 597 5520 ...
Page 43: ...5 Insert or Remove Your Sensor ...
Page 54: ...Customer Care 1 866 597 5520 ...
Page 55: ...6 Attach Your Transmitter ...
Page 61: ...7 Calibrate Your System Test Blood Glucose Manually ...
Page 74: ...Customer Care 1 866 597 5520 ...
Page 75: ...8 Set Review or Change the Alarm Settings ...
Page 89: ...9 Daily Use ...
Page 96: ...Customer Care 1 866 597 5520 ...
Page 97: ...10 Respond to Alarms Errors and Problems ...
Page 119: ...11 Add Events ...
Page 125: ...12 Review Reports and Edit Events ...
Page 135: ...13 Clean Your System ...
Page 136: ...Section 13 Key Terms n Receiver n Transmitter n Contact Points Customer Care 1 866 597 5520 ...
Page 139: ...14 Link and Unlink Your Transmitter and Receiver ...
Page 144: ...Customer Care 1 866 597 5520 ...
Page 145: ...15 Reset User Settings ...
Page 146: ...Customer Care 1 866 597 5520 ...
Page 149: ...16 Change Country Settings ...
Page 155: ...17 Appendix A Site Maintenance ...
Page 158: ...Customer Care 1 866 597 5520 ...
Page 159: ...18 Appendix B Specifications ...
Page 173: ...19 Appendix C FCC Compliance Information ...
Page 174: ...Customer Care 1 866 597 5520 164 Section 18 Appendix B Specifications ...
Page 182: ...Customer Care 1 866 597 5520 ...
Page 183: ...20 Glossary ...
Page 184: ...Customer Care 1 866 597 5520 174 Section 19 Appendix C Classification Compliance Declaration ...
Page 191: ...21 Index ...
Page 192: ...Customer Care 1 866 597 5520 ...
Page 195: ......