background image

8. 

CLEANING AND MAINTENANCE

Due  to  longer  life  of  fireplace  and  its  proper  operation,  it  is  necessary  to  properly 
maintain fireplace, both during firing and after that.
Space for ash and opening for airflow below regulator flap (when removed ashtray, 
opening is located on the right hand side) must be regularly cleaned. Fireplace must be 
cleaned from time to time against grime, at least once a month, because grime and tar 
that settle during combustion on internal surfaces of the burner increase consumption 
of fuel and reduce utilization degree. Manufacturer recommends usage of chemical 
agent 

ASTRATHERM

, which facilitates mechanical removal of residual combustion 

products.

Do not clean external fireplace surfaces with abrasive sponge, because it may  damage 
protection, but with damp cloth with usage of soft cleaning agent. It is not allowed to cool 
down the fireplace using by damping the burner. After cessation of heating season, you 
must carry on with complete fireplace cleaning. Water should be exhausted only in the 
case  if  it  is  necessary  to  carry  out  some  installation  repair.  After  heating  season, 
manufacturer recommends to hang linen bag into the burner space, filled with 1-2 kg of 
chopped limestone.

9. DISMANTLING AND REMOVAL

After finalization of working validity of this product, it is necessary to release the product 
from mains connections, water connections and heating installation, exhaust the water 
and had it over to the companies involved in waste collection/ recycling.
Symbol   „recycle bin with strikethrough“ (on figure) according to European directives, 
warns you about your obligation to deal with inapplicable products with care.

8

Summary of Contents for VOLCANO

Page 1: ...USER MANUAL FOR SOLID FUEL STOVE VOLCANO 24kW ...

Page 2: ...advice and technical assistance Yours sincerely Prior to the use of these fireplaces for central heating read carefully this instruction since it gives you important information regarding safe installation use and maintenance of these devices INSTRUCTION CONTENT 1 Purpose and specific characteristics of these fireplaces 2 Safety 3 Description and technical characteristics 4 Transport and storage 5...

Page 3: ...bility of fireplace operation These fireplaces for central heating are so constructed and made to provide maximal safety during operation on condition that users in all matters adhere to this INSTRUCTION No liability is assumed for injury of people animals or damages of property which is the consequence of failure to adhere to this instruction Any other use of fireplace is considered inappropriate...

Page 4: ...r factor may offer to you in our assortment reductions which change existing condition to the following dimensions Ø 120 Ø 130 or Ø 150 VULKAN FIREPLACE 24 21 3 10 150 30 90 2 5 145 575 1015 480 TECHNICAL DATA Total power kW Power given as radiation kW Required drought Pa Mass total weight kg Water quantity l Max working temperature C Max working pressure bar Smoke pipe diameter mm Width L mm Dept...

Page 5: ...t not be made of flammable materials otherwise distance from the fireplace must be at least 100 150cm b In no case you should put shelves or similar wooden furniture above fireplace c Wall in contact with back of fireplace must be made of heat resistant material d Curtains must not be placed directly behind fireplace and on the side as far as possible e Flammable materials e g door frames wallpape...

Page 6: ...nd setting smoke cap Sealed Sealed Sealed Appropriate connection of the fireplace to chimney Pipe Pipe Opening for cleaning is sealed Opening for cleaning is sealed Inappropriate connection of fireplace to chimney Opening for cleaning Opening for cleaning Opening for cleaning is sealed Opening for cleaning ...

Page 7: ...arantee is null All connections on fireplace must be well sealed which should be visually checked prior to commissioning Mounting procedure is finished with water filling of entire fireplace and entire installation up to the necessary pressure FIREPLACE MAY NOT BE USED WITHOUT WATER Fig 5 Diagram of the connection of fireplace to central heating open system 3 4 9 5 11 2 13 10 12 12 1 14 15 6 7 8 1...

Page 8: ...n combustible materials and located out of the place with stored fuel 6 1 FIRST FIRING Ÿ At the first firing following conditions must be observed Ÿ chimney must be cleaned and properly connected to the fireplace Ÿ fireplace and heating installation must have installed all safety devices Ÿ system must be filled with water and vented Ÿ within the operating mode of the fireplace burner door must be ...

Page 9: ... regulator depends on desired ambient temperature Important note In order to make draught regulator work properly it is necessary to connected fireplace to the chimney of proper dimensions Space between regulator flap and opening for airflow must be cleaned from time to time and to remove residual ash and other combustion products Avoid low water temperatures in the fireplace 50 60 C because it ma...

Page 10: ...asive sponge because it may damage protection but with damp cloth with usage of soft cleaning agent It is not allowed to cool down the fireplace using by damping the burner After cessation of heating season you must carry on with complete fireplace cleaning Water should be exhausted only in the case if it is necessary to carry out some installation repair After heating season manufacturer recommen...

Page 11: ......

Reviews: