4. TRANSPORTATION AND STORAGE
Fireplace is protected by packaging which is not resistant to atmosphere influence. It
should be stored in covered space. Transport to user is done as under contract. After
you remove packaging off the fireplace, check for damages during transport and
handling. In case of doubt that it is not operational, contact seller or directly factory
''ABC PROIZVOD''.
5. SETTING/INSTALLATION
Design, setting and installation of central heating is strictly done by a professional.
In case of poor system design and any defects on installation of system by such person,
which further may cause defective operation of the fireplace, complete material liability
and new expenses are solely born by the person entrusted with installation of heating
system, not the manufacturer, representative or seller of fireplace. Fireplace may be
set in kitchen block or on some other appropriate place (living room), on condition to
provide fireproof base, sufficient space for handling, aeration of the room and
appropriate chimney.
During setting of the fireplace care must be taken of the following:
a)
Furniture and objects that are next to the fireplace must not be made of flammable
materials, otherwise distance from the fireplace must be at least 100-150cm.
b)
In no case you should put shelves or similar wooden furniture above fireplace.
c)
Wall in contact with back of fireplace, must be made of heat resistant material.
d)
Curtains must not be placed directly behind fireplace, and on the side as far as
possible.
e)
Flammable materials, e.g. door frames, wallpaper, must be away from smoke pipes
at least 20cm. This may be decreased if smoke pipes have appropriate thermal
insulation.
f)
Fireplace should be placed horizontally or you should elevate a little back side (2-
4mm).
5.2. CONNECTION TO THE CHIMNEY
Being the very important element of the central heating system, chimney must be of
appropriate cross section, regularly set, regularly installed above roof and insulated
(Fig. 4). Setting dimensions, check of the existing chimney is done by designer of
central heating installation based on the fireplace capacity, fuel type and required
drought for the fireplace.
Fireplace achieves stated power only if chimney has appropriate dimensions.
All connections of smoke pipes of the fireplace must be properly sealed (Fig. 3)
Chimney must be properly above the roof according to instructions (fig. 4) Avoid placing
chimney caps if they have side blinds. For a potential placement of a chimney cap apply
recommendation on fig. 4.