10. PELLET POWER SETTINGS
Press on the main screen.
Press the field “Combustion Management” and then “Pellet Power “
Select the desired power by pressing the card (from 1 to 5) or select
the automatic mode on the next page (press ). The automatic mode
is reflected in the following:
- The pellet power is automatically selected based on the set
temperature and current water temperature in the boiler:
Example:
Water T C°
≤70
71
72
73
74
≥75
Pellet power
5
4
3
2
1
Modulation
Set T
To return to the home screen press
11. SET TEMPERATURE SETTINGS
Press on the main screen.
Press “Heating Management” and then “Boiler Thermostat”.
or increase or decrease the value .The limit values range from
50°C to 80°C.
To return to the home screen press