Industrial Tracker Reference Guide FW 1.8 V0.2
Example:
To modify the transmit strategy to 2, the command
0x0B050E00000002
should be sent.
Descripton:
(0x0B): set the parameter
(0x05): tith an ack token of 5
(0x0E):
transmit_strat
parameter
(0x 00 00 00 02): to a value of 2
7.6.5
Miscellaneous parameters
Parameter
ID
Unit
Range
Descripton
pw_stat_period
0x02
seco
nd
0, 300 i 604800
Period of the Energy status report.
When 0, no energy status report is transmited.
config_flags
0x0D
none 0i0xff
Confguraton lags:
bit 0: Frame pending mechanism
(1)
bit 1: Reserved, not used in industrial tracker
bit 2: Reserved, not used in industrial tracker
bit 3: Send a confguraton uplink message in response to a
confguraton modifcaton dotnlink. Used to confrm the
acton.
bit 4: WIFI payload tith Cypher (0) or tithout Cypher (1)
(2)
bit 5: Reserved, not used in industrial tracker
bit 6: First WIFI scan then geolocaton starts. If disabled (0),
WIFI positon is replaced by a
geoloc start
message
(3)
bit 7: Reserved, not used in industrial tracker
bit 8: Set to enable the sending of a
moton start
message
(3)
bit 9: Set to enable the sending of a
moton end
message
(3)
bit 10: Reserved, not used in industrial tracker
bit 11: Reserved, not used in industrial tracker
Notes
for more details
2) In old frmtare version WIFI positon payload tere all encrypted, this parameter is for
backtard compatbility only and only nonicyphered payload should be use in net
applicaton
to have details about
geoloc_start
,
moton_star
t and
moton_end
payload
7.6.6
Accelerometer parameters
Parameter
ID
Unit
Range
Descripton
motion_sensitiiitt
0x14
%
0i100
Accelerometer confguraton.
0 is default confguraton.
1i100 confgures the accelerometer sensitvity
from 1 to 100%.
Page 36 of 46
10th July 2019
Restricted distribution