Read Capacity Command Data Returned
7
6
5
4
3
2
1
0
0
B
B
B
B
B
B
B
B
1
B
B
B
B
B
B
B
B
2
B
B
B
B
B
B
B
B
3
B
B
B
B
B
B
B
B
4
L
L
L
L
L
L
L
L
5
L
L
L
L
L
L
L
L
6
L
L
L
L
L
L
L
L
7
L
L
L
L
L
L
L
L
B = last logical block (MSB first)
L = block length in bytes (MSB first)
Read and Write
This command passes data in blocks to or from the disk(s). If the
specified block(s) are out of range, check condition/illegal
request/logical block out of range is returned. If SCSI/Ethernet
control is disabled, check condition/vendor-unique/0X81 is
returned and the relevant error code is set in the Mode Sense data.
The vendor-unique additional sense code follows the Mode Sense
error codes with the top bit set.
Read (6) Command
7
6
5
4
3
2
1
0
0
0
0
0
0
1
0
0
0
1
0
0
0
B
B
B
B
B
2
B
B
B
B
B
B
B
B
3
B
B
B
B
B
B
B
B
4
L
L
L
L
L
L
L
L
5
–
–
–
–
–
–
–
–
VideoTools Diskus
Operations
5-84
Applications
9100-0217-02 - SEP 95
Summary of Contents for Diskus
Page 1: ...Diskus Digital Disk Recorder Manual ...
Page 477: ...NOTES Diskus Operations Index 9100 0217 02 SEP 95 Index xvii ...
Page 478: ...NOTES Index Diskus Operations xviii Index 9100 0217 02 SEP 95 ...
Page 479: ...NOTES Diskus Operations Index 9100 0217 02 SEP 95 Index xix ...
Page 480: ...NOTES Index Diskus Operations xx Index 9100 0217 02 SEP 95 ...