2 = 601-2
3 = reserved
4 = reserved
5 = SCSI/Ethernet
6, 7 = reserved
e = last known error code (cleared by Mode Select command)
0 = OK, no error
1 = SCSI/Ethernet control disabled
2 = clip permission denied
3 = outside clip limits
4 = Mode Select parameter error
NOTE: Lower case letter values are available only
with Mode Sense.
All parameters take effect until reset by another Mode Select
command. After setting new parameters, issue a Read Capacity
command to determine the block size, which is the same as
specified, if legal, and last block parameters. Changing the data
format or windows parameters affects the last block, but
changing the field/frame value does not. Changing any
parameter affects the number of blocks needed to transfer a full
image.
Mode Sense Command
This command reads the current data format and window
parameters for current transfers. The data returned is the same as
Mode Select data above.