Power Requirements
Use a +12VDC power supply rated at 1 amp as a local supply for
the Control Panel when the cable length exceeds 150 feet (45
meters). A suitable power supply with the proper connector
attached, part number 9502-0005 for 110V and 9501-0000 for 220V,
is available from Abekas. Connect the power into the Control In
connector, if this is the first or only panel, or into the Main Chassis
connector if this is the second panel. Pins 1 (+12VDC) and 9
(+12VDC return) are used for the power input. In systems with
multiple Control Panels, you must locally power all panels after
the first one, regardless of distance.
Diskus
Control Panel
15-pin Male
Signal
9-pin Male
1
+12VDC Power
1
2
Not Used
2
3
+RS-485
3
4
Signal Ground
4
5
Not Used
N/A
6
Not Used
6
7
Not Used
7
8
-RS-485
8
9
+12VDC Return
9
10
Not Used
N/A
11
Not Used
N/A
12
Chassis Ground
5
13
Not Used
N/A
14
Not Used
N/A
15
Not Used
N/A
Control Panel Cable Pinout Table
Diskus Technical Guide
Connecting Diskus