Configuring the Hardware
The GPI configuration jumpers are located on the Diskus Main
Board, in the front right hand corner. See the figure above. You
must remove the disk tray to access the jumpers. See Section 8 –
Chassis for details.
To jumper for a dry closure, use both jumpers as shown. To
jumper for isolated closure, use only a single jumper across the
center two pins (2 and 3). Place the extra jumper on one of the
remaining pins for storage.
JP6
JP6
JP4
JP4
JP2
JP2
JP3
JP3
"Dry" Example
Isolated Example
GPI 1 = JP2
GPI 2 = JP6
GPI 3 = JP4
GPI 4 = JP3
Front
1
1
2
2
3
3
4
4
GPI Jumper Locator
Connecting Diskus
Diskus Technical Guide
7-30
Installation
9100-0217-02 - SEP 95