Parameter Settings
Description
V Blanking
Off
Disables blanking of the vertical interval.
On
On
Enables blanking of the vertical interval.
Analog Ref
Off
External analog reference disabled.
On
External analog reference enabled.
V Phase
Numeric
Adjusts vertical output video phase. Range
is
±
8 lines.
H Phase
Numeric
Horizontal output video phase in
approximately 37 ns steps (1/2 pixel clock
rate). Range is -858 to +857.
Fine H Phase
Numeric
Fine horizontal output video phase timing
in approximately 4.6 ns steps. Range is from
-4 to +3.
Clips
Off
Hides Clip menu in GUI and when scrolling
through menus with the Control Panel.
On
Enables Clip menu in GUI and when
scrolling through menus with the Control
Panel.
Auto
Enables clips to be defined with each
recording.
VITC line 1
10 - 20
Allows placement of the first line of VITC
on Diskus’ output on any line between 10
and 20 inclusive. The default setting is line
12.
Engineering Menus