When then coolant flows through the discharge hose into the device’s filler neck, the device bleeding is
finished and the cable assembly can be bled.
6.2.2 Bleeding the cable assembly on page EN
If coolant does not flow through the discharge hose, the following steps must be taken:
4
Insert the free end of the discharge hose in the device's filler neck and fix
by hand.
5
Switch on the device.
6
Switch off the device.
7
Remove the discharge hose from the blue-colored quick coupling and
position the collection receptacle in front of the device.
8
Connect the discharge hose to the drain coupling and blow a small amount
of coolant into the collection receptacle.
9
Remove the discharge hose from the drain coupling.
10
Connect the discharge hose to the blue-colored quick coupling.
11
Insert the free end of the hose in the filler neck and fix by hand.
12
Seal the discharge hose or kink it and then open it abruptly. Repeat this
process until coolant flows into the filler neck.