ABICOOLER 1300
9 Maintenance and cleaning
EN
-
15
9 Maintenance and cleaning
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
9.1 Maintenance and cleaning intervals
The specified intervals are standard values and refer to single-shift operation. When using arc welding
equipment, always observe the provisions of EN 60974-4 Inspection and testing, as well as any national
laws and regulations.
WARNING
W
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
CAUTION
W
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
► Leave the device switched off throughout the entire bleeding process.
Daily
► Check coolant level and top up, if necessary.
► Check couplings and grommets for leaks and adjust or replace as
needed.
Monthly
► Blow out the air head exchanger with compressed air from the outside
and remove all dust.
► Check the coolant supply and return hoses for dirt and debris and
replace if necessary.
Every six months
► Change the coolant.
9.2 Change the coolant on page EN
► Flush the supply/return lines against the flow direction.
► Rinse the coolant tank.
► Flush the coolant circuit with clean water.
► Check external connections for leaks and tighten hose clamps using
pliers as needed.
► Check coolant hoses for damage.