EN - 8
3 Product description
ABIDOT
3 Product description
3.1 Technical data
3.2 Abbreviations
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and
material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without
authorisation.
• The device may only be used by qualified personnel (in Germany, see
TRBS [Technical Rules for Operating Safety] 1203).
Transport and storage
- 10 °C to + 55°C
Relative humidity
up to 90 % at 20 °C
Operation
- 10 °C to + 40°C
Tab. 1
Ambient conditions
Laser protection class:
EN 60825-1; 2007
2
M /
670 nm / 2.5 mW
Input:
100 - 240 V AC/ 150 mA / 50 - 60 Hz / 10 - 20 VA
Output:
5 V DC 500 mA
Protection class:
IP3X
Tab. 2
General data
AC
Alternating current
DC
Direct current
SO Stick-out
Free wire end (measured from the contact tip end)
Tab. 3