ABIMIG
®
SpinArc
®
9 Maintenance and cleaning
EN - 15
Refer to the maintenance schedule for checking, cleaning and replacing components. For assembly and
disassembly of the individual components, proceed as shown in the following diagram:
1
Use a wire brush to clean components to which weld spatter generally adheres and scour with
compressed air. Mount or replace.
2
Check all cables and plastic sheaths for damage and soiling and replace if necessary.
3
Check that all connections are secure.
4 ABICOR BINZEL
offers factory repair services.
9.1 Replacing the contact tip
Fig. 8 Maintenance and cleaning on page EN-15
1
Hold the tip adaptor extension
2
Remove the contact tip
with a wrench. Check it and, if necessary, clean or replace it.
3
Re-attach the contact tip
1
Central connector
2
Cam
3
O-ring torch body
4
Cap
5
Gas nozzle
6
Contact tip
7
Tip adaptor extension
8
Outer flexure fastener
9
Inner flexure fastener
10
Flexure
11
Tip adaptor
12
Spin shaft
13
Power stud
Fig. 8
Maintenance and cleaning
1
2
3
4
5
6
7
8
9
10
12
13
11
NOTICE
• The flexure
may be damaged when you replace the contact tip.
• The contact tip
must be positioned securely.