EN - 20
BAL.0533.0 • 2019-11-15
9 Maintenance and cleaning
FEC
9.4 Changing the filter
1
Switch off the power to the fume extraction system.
2
Dedust the filter cartridge before changing the filter and empty the filter housing.
9.2 Filter dedusting on page EN-18 and 9.3 Emptying the filter housing on page EN-19
9.4.1 Replace the protective underlay
1
After the system has been dedusted, disconnect the FEC from the compressed air connection.
2
Unlock
the filter housing
.
3
Tip the filter housing
forward.
4
Place the protective underlay
(in the package with the new filter cartridge) on the extraction system.
CAUTION
• Check and wear your personal protective equipment.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves and safety shoes.
• Personal protective equipment must be worn when in the vicinity of the dust collecting bag as it is being filled with the
separated dust.
NOTICE
• The filter must be changed if, after multiple dedustings, the "Dirty" LED is still illuminated and no other error
has occurred.
1
Filter housing
2
Housing
3
Latch
4
Protective underlay
Fig. 12
Replace protective underlay
1
2
3
4