FILTRATION & CHANGING FILTERS
Important note:
Always clean the pre-filter (unless recently cleaned) and restart the machine. If the alert continues, change the pre-filter
(unless recently changed). If alert continues change the main filter and restart the machine.
Changing filters
Always wear the appropriate PPE when coming into contact with used filters or cleaning the pre-filter.
Cleaning the pre-filter
•
Switch off Purex machine
•
Attach compressed air connection
•
Turn lever to let compressed air enter the cleaning mechanism
•
Shut the valve, disconnect the airline and allow debris to settle
•
Use tray to remove debris, refit tray, restart machine
Changing the pre-filter
•
Remove the lid, earth strap
•
Remove the nuts holding the pre-filter compression plate (7) in place
•
Remove the plate and remove the pre-filter (2)
•
Insert a new filter, refit the compression plate and earth strap
•
Fit and lock the lid and restart the machine
Changing the main filter
•
Remove the lid, earth strap
•
Lift and remove the main filter (6)
•
Insert new main filter (6) ensuring it sits correctly around the locating brackets, with airflow arrow pointing down.
•
Refit earth strap, the lid and restart the machine
(Purex recommend the pre-filter is also changed unless it has been changed recently)
INTERFACING
POWER
Interface Socket
When not in use this socket is protected by a screw-on cap.
Interface Switch
To enable interfacing move the
switch to the ‘II’ position,
unscrew the interface socket cap and plug in
the amp clamp. Connect the amp clamp in the correct orientation to the welding torch. Please note there will be a
small delay from starting the welding process to the extraction unit being up to speed. When the welding has been
stopped the extraction unit will continue to run to capture any remaining fume for a short period before going into
standby mode.
Power Socket
Connect the power cable provided to this socket.