EN
-
26
7 Operation
iROB
®
501, iROB
®
401, iROB
®
301
7.1.2 Activating the control panel lock
The control panel lock function prevents the welding parameters from being changed by mistake. The control
panel lock only permits wire feed and retraction movements, gas tests, and parameter saving. Switching
off the device does not cancel the control panel lock. Resetting the welding parameters and the internal
functions deactivates the control panel lock.
The parameter protection function can be used to give only a selected group of persons permission to
change parameters. The parameter protection function can only be canceled by entering a password.
7.1.1 Password-protecting the welding parameters on page EN
7.2 Overview of welding parameters and processes
7.2.1 Overview of welding parameters
► Press and hold <Enter> for at least 3 seconds.
The control panel lock is activated.
In the event of an operating error, the LED above the <Enter> button flashes.
► Press and hold <Enter> again for at least 3 seconds.
The control panel lock is deactivated.
The LED above the <Enter> button is extinguished.
(3 sec.)
(3 sec.)
Tab. 9
Welding parameters
Welding parameters
Adjustable range
Starting value
Description
Pre-flow period
0 to 10 s
0.1 s
Defines the duration of the gas flow
prior to the start of welding.
Start welding
parameter
Main welding
parameter
End crater filling
parameter
Power supply
20 to 550 A
(iROB 501)
20 to 400 A
(iROB
®
401)
20 to 300 A
(iROB
®
301)
--
Start welding parameter:
Defines the welding current/voltage
immediately after welding starts.
Main welding parameter:
Defines the welding current/voltage
during welding.
End crater filling parameter:
Defines the welding current/voltage at
the end of welding.
Voltage
(manual)
10 to 50 V
(iROB 501)
10 to 50 V
(iROB
®
401)
10 to 50 V
(iROB
®
301)
--
Voltage
(arc length
correction)
−10 to 10
0
Post-flow period
0 to 10 s
0.4 s
Defines the duration of the gas flow
after the arc is extinguished.
Arc characteristic
−10 to 10
0
Varies the arc characteristic from
soft (+10) to hard (−10).
Memory location number in the job
memory
1 to 100
1
Memory location number for welding
parameter sets.
iArc mX Move DC frequency
0.5 to 32.0 Hz
3.0 Hz
Sets the frequency during
iArc mX Move DC welding.