Setting the gas pre-flow post-flow time
Setting the welding current
1
Press the <Parameter selection> button repeatedly until the
<Gas pre-flows> or <Gas post-flow-flows> LED is selected.
2
Set the gas flow period with the <Parameter setting> knob.
The value is displayed in the left digital display.
1
Press the <Parameter selection> button repeatedly until the
<Main welding parameter>, <Start welding parameter>,
or <End crater filling parameter> LED illuminates.
2
Verify that LED <A> (amperes) is illuminated.
3
If it is not, press the <Toggle welding current/wire feed
speed> button.
The welding current can also be set based on the
wire feed speed.
The LED does not illuminate: Current-based.
LED on: Based on the wire feed speed.
4
Set the current with the <Parameter setting> knob.
The value is displayed in the left digital display.
V
±
A
m/min.
IE
I
6
A
m/min.