iROB
®
501, iROB
®
401, iROB
®
301
7 Operation
EN
-
41
F35: Saving necking detection sensitivity
Defines whether necking detection sensitivity automatically corrected by function is reset to the preset value
after the welding process ends.
1
Set internal functions F36/F37.
2
Activate internal function F34.
If the free welding wire end and the welding conditions are subject to dramatic changes between
the welding processes, switch off this function.
F36/F37: Adjusting spatter control (P1P/P2P)
This function is available only if the internal function F34 is deactivated.
1
Switch off internal function F34.
2
Display internal function F36 (spatter adjustment P1P) and perform the welding process with this display.
3
Increase or decrease the value of internal function F36 and perform the welding process again.
4
Repeat this step within the adjustable range −100 to 100 until the desired result is achieved.
5
Display internal function F37 (spatter adjustment P2P) and perform the welding process with this display.
6
Increase or decrease the value of internal function F37 and perform the welding process again.
7
Repeat this step within the adjustable range −100 to 100 until the desired result is achieved.
F38: Switching on advanced welding circuit resistance measurement
The arc voltage can be determined via the corresponding welding power source terminal.
Use the optional arc voltage test line with a line length ≥ 30 m. Switch the direct arc voltage detection
terminal to the component-side welding power source terminal or the wire feeder terminal. Extending the
welding power supply line without a component-side test line connection can dramatically increase
the amount of spatter generated. In this case, use of the optional arc voltage test line can drastically limit the
amount of spatter.
F43: CAN ID
If several welding power sources are connected to a PC monitoring system, the ID for the CAN bus can
be set here.
Adjustable range
ON/OFF
Default value
OFF
Storage option
Yes
Description
OFF: Necking detection sensitivity is not saved.
ON: Necking detection sensitivity is saved.
Adjustable range
−100 to +100
Default value
0
Storage option
F36: Yes
F37: No
Description
Sets the control parameters for spatter control.
Adjustable range
ON/OFF
Default value
OFF
Storage option
No
Description
OFF: Arc voltage detection input inactive.
ON: Arc voltage detection input active.
Adjustable range
1 to 16
Default value
1
Storage option
No
Description
Defines the CAN ID number to be used with the PC monitoring
system, etc.