iROB
®
501, iROB
®
401, iROB
®
301
7 Operation
EN
-
43
F52: DataLOG function data types
This function allows the user to select data that can be saved with the DataLOG function.
F53: Setting the scanning frequency for the DataLOG function
Tab. 14
DataLOG function data types
Setting
Welding
current
(command
value)
Welding
current
(recognized
value)
Welding
voltage
(command
value)
Welding
voltage
(recognized
value)
Wire feed
speed
(command
value)
Wire feed
speed
(command
value)
0
---
---
---
---
---
---
1
---
Can be saved
---
Can be saved
---
Can be saved
2
Can be saved
---
Can be saved
---
Can be saved
---
3
Can be saved
Can be saved
---
Can be saved
---
---
4
Can be saved
Can be saved
---
---
---
Can be saved
5
---
Can be saved
Can be saved
Can be saved
---
---
6
---
---
Can be saved
Can be saved
---
Can be saved
7
---
---
---
---
Can be saved
Can be saved
8
---
---
---
Can be saved
Can be saved
Can be saved
Adjustable range
0 to 8
Default value
0
Storage option
No
Description
Defines which data is written to the DataLOG:
0: No data
1: Welding current/welding voltage/sequence information
2: Current command/voltage command/wire feed command
3: Current command/welding current/welding voltage
4: Current command/welding current/sequence information
5: Welding current/voltage command/welding voltage
6: Voltage command/welding voltage/sequence information
7: Welding current/wire feed command/sequence information
8: Welding voltage/wire feed command/sequence information
Tab. 15
Scanning frequency for the DataLOG function
Setting
Scanning interval
1
10 ms
2
100 ms
3
1 s
Adjustable range
1 to 3
Default value
1
Storage option
No
Description
Defines the scanning speed of the DataLOG function.