EN
-
48
7 Operation
iROB
®
501, iROB
®
401, iROB
®
301
7.6.3 Recalling a saved job
7.6.4 Deleting a job
Deleted data cannot be restored.
1
Press the <Load> button.
The system switches to load mode and the LED above the
<Load> button illuminates.
The job no. (memory location number) is displayed blinking
in the right digital display and the <JOB No.> LED is
illuminated.
The welding current saved under this job no. is displayed in
the left digital display and the LED <A> is illuminated. If no
value is saved, <
- - -
> is displayed.
2
Select the desired memory location number (job no.) using
the <Parameter setting> knob.
If no value is saved under the selected job no., <
- - -
> is
displayed in the left digital display.
If a value is saved under the selected job no., it is displayed
in the left digital display. At the same time, the LEDs above
the <Operating mode> or <Welding wire material> buttons
illuminate.
3
Press <Enter>.
The LED above the <Enter> button blinks.
The saved values blink in the left/right digital display.
4
Press the <Parameter selection> button.
The saved values blink in the left/right digital display.
5
Adjust the values accordingly.
6
To change the job no., press the <Save> button.
7
Press <Enter>.
The welding parameters are saved to the selected job no.
and the system exits the save function.
A
m/min.
sec.
Hz
±
V
%
JOB.No.
1
Set the main switch to <0>.
2
Press and hold the <Save> and <Load> buttons
simultaneously and set the main switch back to <I>.
3
Press and hold both buttons until <dEL> is displayed in
the left digital display.
4
Release the buttons.
As long as <dEL> is displayed in the left digital display,
the welding power source is in delete mode.
The selected job no. is displayed blinking in the right digital
display and the <Job no.> LED is illuminated.
+
A
m/min.
sec.
Hz
±
V
%
Job-No.