13 IFR-800 fieldbus connection tool
iROB
®
501, iROB
®
401, iROB
®
301
PROFIBUS
DeviceNet
Tab. 22
PROFIBUS basic properties
Communication standard
PROFIBUS-DP
Baud rate (speed)
Support of all common baud rates up to 12 MBit/s
(automatic detection)
Connector
IEC 61076
-
2
-
101, M12, 5-pin, B-coded, socket
Node address
Default setting: 77
The setting can be made with the configuration switch from
Anybus Communicator AB7000.
Connection
Only I/O connection supported, operation as slave
Communication cycle
Recommended: 5 to 200 ms
Data scope
32 bytes ON/OFF
Fig. 16
PROFIBUS pin assignment
A
Pin 1 = not assigned
B
Pin 2 = cable A (green)
C
Pin 3 = not assigned
D
Pin 4 = cable B (red)
E
Pin 5 = not assigned
Housing = shielding
D
C
B
A
E
Tab. 23
DeviceNet basic properties
Communication standard
DeviceNet
Baud rate (speed)
Default setting: 500 kbps
The setting can be made with the configuration switch from
Anybus Communicator AB7001.
Connector
MSTB 2.5/5-ST-5.08 AU from PHOENIX CONTACT or a
product of similar quality.
Node address
Default setting: 1
The setting can be made with the configuration switch from
Anybus Communicator AB7001.
Connection
Only I/O connection supported, operation as slave
Communication cycle
Recommended: 5 to 200 ms
Data scope
32 bytes ON/OFF
Fig. 17
DeviceNet pin assignment
A
Pin 1 = V−
B
Pin 2 = CAN L
C
Pin 3 = shielding
D
Pin 4 = CAN H
E
Pin 5 = V+
A
B
C
D
E