EN - 6
BAL.0523.0 • 2019-10-17
3 Product description
iSTM mini
The load data was determined under standard conditions, at low to medium heat of reflection, free air circulation and an
ambient temperature of approx. 28° C. When used under more strenuous conditions, the load data must be reduced by
10–20%.
3.2 Abbreviations
NOTICE
• Torsion A4 and A6 max. ±355°.
• To ensure proper attachment of the
iSTM mini
and cable assembly, you must set the 4th and 5th axes of the robot as
follows: 4th axis = neutral position, 5th axis = tilted by 10°, 6th axis = neutral position
ABIROB
®
G
ABIROB
®
W
Type of voltage
DC
Polarity of the electrodes
Usually positive
Wire types
Commercially available round wires
Type of use
Automatic
Voltage rating
Peak value of 141 V
Protection type of the device
connections (EN 60529)
IP3X
Shielding gas (EN ISO 14175)
CO
2
and M21
Tab. 5
General torch data with reference to EN 60974-7
Type
Type of
cooling
Load
1
1For pulse arcs, the load data is reduced by up to 35%
Duty
cycle
Wire ø
Gas flow
Cooling data
Cooling
capacity
Flow
Flow pressure
CO
2
M21
Min.
Min.
Min.
Max.
ABIROB
®
A
A
%
mm
l/min
W
l/min
bar
bar
G350
Air
350
300
100
0.8–1.2
Approx. 20
800
Approx. 20
/
/
G360
Air
360
290
100
0.8–1.6
Approx. 20
800
Approx. 20
/
/
G500
Air
500
400
100
0.8–1.6
Approx. 20
800
Approx. 20
/
/
W300
Liquid
330
300
100
0.8–1.2
Approx. 20
800
1.25
1.5
3.5
W500
Liquid
550
500
100
0.8–1.6
Approx. 20
800
1.25
1.5
3.5
W600
Liquid
600
100
100
0.8–1.6
Approx. 20
800
1.25
1.5
3.5
Tab. 6
Product-specific torch data (EN 60974-7) in connection with iSTM mini
ABIROB
®
G
Automatic welding torch, air-cooled
ABIROB
®
W
Automatic welding torch, liquid-cooled
Tab. 7