4 Product description
xFUME™ ADVANCED 115V – CSA
4.2 Control elements and connections
4.3 Technical data
Abb. 3
Control elements/ports
A
Service LED
B
Operation LED
C
Power LED
D
Hour meter
E
<Auto/Manual> switch
F
<On/Off> switch
G
Mains connecting cable
H
Output regulator
I
Fuse
J
Current clamp port 1
K
Current clamp port 2
<Auto/Manual> switch (E)
The automatic starting function is activated when the switch is set to
<Auto>. If the switch is set to <Manual>, the automatic starting function is
inactive and the device must be switched on and off manually.
Service LED (A)
The device is equipped with a safety device to monitor the minimum air
volume flow to be extracted. A differential pressure switch is used for
monitoring purposes. The service LED illuminates in continuously when
both filter cartridges are not functioning properly or are saturated and
must be replaced. During initialization, the service LED and the power
LED flash alternately.
Operation LED (B)
The operation LED illuminates continuously when the motor is running.
During initialization, the power LED and the service LED flash alternately.
Power LED (C)
The power LED illuminates continuously if the device has been switched
on by the <On/Off> switch.
A
G
B
C
D
E
F
H
I
J
K
Tab. 1
General information
xFUME™ ADVANCED 115V – CSA
Connection voltage
115 V
Rated frequency
60 Hz, 2.0 kW
Rated current
18 A
Drive power
2 × 1.0 kW
Filter surface
2 × 0.63 m²
Connection diameter
58.8 mm
Max. air volume flow
1
350 m³/h
Sound pressure level LpA
< 75 dB (A)