9 Maintenance and cleaning
EN
-
21
9.1 Maintenance and cleaning intervals
The specified intervals are standard values and refer to single-shift operation. We recommend recording the
inspections. The date of the inspection, the detected defects and the name of the inspector must be observed.
9.2 Emptying the dust collecting drawer
After 2 operating hours or
no later than when the
service LED illuminates
► Run the cleaning process.
► Replace filter cartridges.
9.3 Replacing filter cartridges on page EN
Daily
► Empty the dust collecting drawer.
9.2 Emptying the dust collecting drawer on page EN
Weekly
► Check the operating hours meter.
Monthly
► Check device for visible damage.
After approx.
800 operating hours
► Carbon brushes must be replaced only by a qualified electrician.
9.4 Replacing the carbon brushes on page EN
After two carbon brush
replacements
► Turbines must be replaced only by a qualified electrician.
9.5 Replacing the turbines on page EN
WARNING
Health risk caused by inhaling harmful dust
Improper emptying of the dust collecting drawer can lead to harmful dust and debris penetrating the
ambient air. It can harm the respiratory tract if inhaled.
► Empty the dust collecting drawer into a dust collecting bag immediately after removal.
► Do not clean the device with compressed air.
1
Loosen the star screws on the dust collecting
drawer.
2
Empty the dust collecting drawer into a dust
collecting bag.
3
Close the dust collecting bag and dispose of it in
accordance with local regulations.
4
Reassemble in the reverse order and ensure that
the star screws are tightened by hand.