EN - 20
BAL.0733.0 • 2021-01-11
9 Maintenance and cleaning
xFUME FLEX
9.5 Replacing the extraction arm
CAUTION
Reduced extraction capacity
Damage to the extraction hose and leaks negatively impact extraction performance.
• Check the extraction hose regularly and replace it as needed.
Figure
Action
Without
1
Fold the upper end of the rubber sleeve on the extraction
hood so that the gripping clamp is accessible. Loosen the
gripping clamp screw.
2
Retract the extraction hose.
Without
3
Cut open the cable tie.
4
Disconnect the cable connections.
5
Loosen the screw between the connector and profile tube
and remove the extraction hood.
Without
6
Fold the upper end of the rubber sleeve on the extraction
system so that the gripping clamp is accessible. Loosen
the gripping clamp screw.
7
Remove the extraction hose in the direction shown and
replace it with a new one.
6.2 Mounting the extraction arm on page EN-10
Perform step
and step
.
6.2 Mounting the extraction arm on page EN-10
Perform step
.
Tab. 10
Replacing the extraction hose