EN - 14
BAL.0733.0 • 2019-09-18
8 Putting out of operation
xFUME VAC FLEX
Fig. 5 Control elements on page EN-14
1
Set the Device On/Off switch
on the extraction system to the “On” position.
7.1 Control elements
1
Adjust the extraction arm
to accommodate the work task.
2
Adjust the extraction hood
to accommodate the work task. The extraction hood must be located approx. 20 cm above
the welding point during operation.
3
Establish an electrical connection.
4
Switch on the LED light
on the extraction hood
5
Adjust air volume to the work task.
6
to switch on the device.
8 Putting out of operation
Fig. 5 Control elements on page EN-14
1
to switch off the extraction system.
2
Disconnect the extraction system from the power supply.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
6 Putting into operation on page EN-10
1
Extraction arm
2
Handle
3
Service door
4
On/Off switch
5
4 castors
6
Extraction hood
7
LED light
8
Light switch
Fig. 5
Control elements
8
6
2
3
4
5
7
5