| Installation –
Mechanical installation of the wallbox on the mounting plate
22
10
Remove the right-hand panel in the upper part of
the eMH1 Wallbox housing.
11
Remove the jumper at the switching input
EN1
.
y
The contact
EN1
is located on the charge con-
troller’s circuit board under the built-in units.
EN1
EN1
12
Connect the control cable of the mounting plate via
the reverse polarity protected JST connector to the
switching input
EN1
.
NOTE
Retaining the jumper
Retain the jumper so that you can reinsert it if you want to operate the wallbox without the mounting plate at a
later time. In this case, you will need to reinsert the jumper in contact
EN1
.
WARNING!
Connection to contact EN1 for wallboxes with E2I interface
On all eMH1 wallboxes manufactured from mid-2021 onwards, the E2I interface is located on the inside left-hand
side, and this is connected by default to the switching input
EN1
on the charge controller’s circuit board via a
Installation instructions for the eMH1 Wallbox).
Pull the cable out of
EN1
on one side of the circuit board so that you can connect the control cable of the
1W0001/PVEMH10 mounting plate there.
Make sure the cable is still connected to the E2I interface of the wallbox and lay the cable on the inside of
the wallbox.
If you want to operate the wallbox again without the mounting plate at a later time, you will need to recon-
nect the cable to the switching input
EN1
on the charge controller’s circuit board.