Installation
|
11
Installation
The WHEMH10, 1W0001 and PVEMH10 mounting plates are designed exclusively for installing an eMH1 Wallbox
indoors or outdoors. When operating the eMH1 Wallbox, the following specifications regarding the location and the
connection technology must be met in order to ensure safe operation.
Requirements for the installation site
To operate an eMH1 Wallbox on a mounting plate, you as the operator must adhere to the following specifications
regarding the location and positioning.
Be sure to observe all local regulations for electrical installations, fire prevention and accident prevention.
All guidelines for the installation of low-voltage systems in accordance with IEC 60364-1 and IEC 60364-5-52
apply.
The installation surface must have sufficient strength to withstand the mechanical loads.
A sufficiently dimensioned supply cable for the power supply of the respective wallbox must be provided at the
installation location. If necessary, the supply cable must be protected against mechanical influences by a suitable
hose or pipe.
To ensure safe operation, minimum distances to other technical installations must be observed: you can obtain
further information from your electrical contractor or distributor.
It is important to ensure that the maximum permissible operating temperature is not exceeded due to external
influences such as direct sunlight or similar. Otherwise, adequate cooling or shading must be provided.
WARNING!
Observation of environmental conditions for the eMH1 Wallbox
Always pay attention to all additional environmental conditions for the eMH1 Wallbox. These are listed in the
section “Specifications for the installation location” in the installation instructions for the eMH1 Wallbox:
Installation instructions for the eMH1 Wallbox
Specifications for mechanical installation
The WHEMH10, 1W0001 and PVEMH10 mounting plates can be installed either on a wall or on the POLEMH1 mount-
ing pole.
The process for installing on a wall is described from page 15 onwards.
The process for installing on the POLEMH1 mounting pole is described from page 16 onwards.
The entire installation of the mounting plate should always be carried out by qualified personnel. For mechanical in-
stallation, you will need the following components included:
Drilling template, 1 pc
Mounting pole installation:
M5×20 countersunk screw, 6 pcs
Wall mounting:
Wall plugs (8×40 mm), 6 pcs
Wall mounting:
Countersunk screw (5×60 mm,
T20), 6 pcs