1.1.2. The Advanced Technical Characteristics
l
Market leading light and compact design for modern OA environment and
OEM flexibility.
l
Powerful CPU integrates all power stages, control and communication functions necessary for maximized
UPS protection and functionality, including
Power management status monitoring, configuration setting operation
Scheduling, remote control and self-diagnosis.
l
Slick CPU communication design allows full function remote control from any
computer environment via standard RS-232 interface using Megatec’s
RUPSII protocol.
l
State-of-the-Art IGBT Technology and Industrial Grade quality ensures
Highest efficiency and reliability under worst operating condition.
l
Industry lading inverter protection technology incorporates 2-stage output
Current sensor, smart overload output current control, improved crest factor,
and feedback failure proof circuit, elevating the availability of power service.
l
Guarantees an exclusive protection against DC damage for inductive load,
Such as motor based devices, entirely eliminating application limitation.
l
Advanced Input PFC control guarantees the PF performance and maximum
energy efficiency.
l
Unique electronic over-current protection detects output short-circuit and
faults, and halts output before damages done to output fuse or equipment,
thereby minimizing the need for service.
l
Expanded input voltage working range minimizes battery usage and
enhances battery utilization and life.
l
Automatic Frequency Sensor reduces headache in frequency shift.
l
DC-start function makes sure of the start-up of UPS during power outages.
l
On-demand self-diagnosis function ensures UPS reliability and availability.
l
Built-in supplementary charger enables speediest charging of external battery
Bank.
l
SNMP adapter slot represents the advanced upgrade solution to achieve
direct power management via internet world-wide.
l
User's adjustable Output DIP switches allow you to select an accommodate
Output voltage for your critical device.
Summary of Contents for 3 MS series
Page 7: ...7 1 2 3 4 5 6 7 8 9 Pin 6 RS232 Rx Pin 9 RS232 Tx Pin 7 Ground...
Page 24: ...24 5 2 Fault LED Lights up and No Output FIG 5 2...
Page 32: ...32 6 2 Fault LED Lights up and No Output FIG 6 2...
Page 39: ...39 Appendix a 1 Wiring Diagram a 1 1 For MS 1K...
Page 41: ...41 a 1 3 For MS3K...
Page 42: ...42 a 2 Placements a 2 1 For MS1K 220V...
Page 43: ...43 a 2 2 For MS2K 220V a 2 3 For MS3K...
Page 44: ...44 a 2 3 For MS3K 220V...
Page 45: ...45 a 2 4 For MS1K 120V...
Page 46: ...46 a 2 5 For MS2K 120V...