Unlock Insturctions
Face recognition terminal can control the lock of door through the multi cable connect to system,
in the retention of existing access control system function of the colleague, the access control
intelligent operation upgrade.
If 1.0 mm standard wire is used, 12V switching power supply is used, and the wiring distance from the
site construction (switching power to equipment distance) does not exceed 20 m.
If 1.5 mm standard cable is used, 12V switching power supply is used, and the wiring distance from
the site construction (switching power to equipment distance) does not exceed 30 m.
If 2.0 mm standard wire is used, 12V switching power supply is used, and the wiring distance
(switching power to the equipment distance) is not more than 40 m.