Internet Alert
MH350 Alarm and to prevent the computer which being attacked to
send DDoS packets to LAN network
STEP 1
﹒
Select
Internal Alert
in
Alert Setting
and enter the following settings:
Enter
The threshold sessions of infected Blaster (per Source
IP)
(the default value is 30 Sessions/Sec)
Select
Enable Blaster Blocking
and enter the
Blocking Time
(the default time is 60 seconds)
Select
Enable E-Mail Alert Notification
Select
Enable NetBIOS Alert Notification
IP Address of Administrator:
Enter 192.168.1.10
Click
OK
Internal Alert Setting is completed. (Figure16-1)
Figure16-1 Internal Alert Settings