background image

Model number: A21SM3001

R3a

Summary of Contents for pro A21SM3001

Page 1: ...o 2 in 1 Steam Cleaner User Guide For Customer Services Spare Parts please call 0845 209 7461 Opening times Monday Friday 8am 6pm Saturday 9am 1pm Or visit us at www productcareuk com IMPORTANT RETAIN...

Page 2: ...Guarantee 22 Customer services 23 Spare parts 24 Connection to the mains supply 25 Thank you for purchasing your Abode pro Steam Cleaner Multi purpose steam cleaning has never been so easy with your n...

Page 3: ...cal sensory or mental capabilities or lack of experience and knowledge IF they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards invol...

Page 4: ...ith wet hands Do not pull or carry by cord use cord as a handle close door on cord pull cord around sharp corners or edges or expose cord to heated surfaces Do not unplug by pulling on cord To protect...

Page 5: ...damage the unit Close attention is necessary when used near children Do not store with a wet unit pad still attached Using distilled or demineralized water will maximize the performance of your steam...

Page 6: ...cator light 10 Microfibre mop pad x2 17 Crevice brush 4 Steam dial 11 Round Brush nylon 18 Steam button 5 Tube Release button 12 Small cloth 19 Carpet glider 6 Lower cord hook 13 Squeegee 20 Measuring...

Page 7: ...t the separate components Check the steam unit after unpacking for any visual damage such as Misaligned or damaged parts Damage to the main body and separate components Damage to the plug or cable If...

Page 8: ...lockwise and remove Fill the measuring jug provided with 200ml of cold tap water Empty the measuring jug carefully into the water tank and then add a further 150ml of cold water Place the steam cleane...

Page 9: ...ightening Note It is recommended to empty the water tank before every refill This will prevent issues including overfilling and build up of scale Be careful not to overfill the water tank leave a spac...

Page 10: ...ws ceilings and other hard to reach places in handheld steamer mode For increased support hold the pole in both hands 1 Slot the extension pole into the top of the main unit pushing until it clicks fi...

Page 11: ...d over the surface slowly in order to increase the cleaning action of the steam Fitting the microfibre pad Place the pad toggle at the back of the mop head Hold the mop head steadily and pull the clot...

Page 12: ...ssing the nozzles together until the release button clicks in place It can be used alone and gives concentrated direct steam for cleaning and disinfecting The jet nozzle adaptor can also be used with...

Page 13: ...sembly and locate the squeegee Hook the squeegee on to the assembly over the cloth and push down until it clicks in to position Note Unplug the cleaner and allow to cool before fitting or changing att...

Page 14: ...ve simply pull the small tool off after use fig 3 14 Crevice Brush The crevice brush is ideal for narrow hard to reach areas Use an up and down motion to rub off the dirt Once the steam has broken dow...

Page 15: ...wered and heating If the light does not illuminate refer to page 19 Note A full water tank should provide approximately 15 25 minutes of use Steam time can vary according to volume and temperature of...

Page 16: ...be left behind If this occurs please allow air dry time Steam cleaning on all hard sealed floors will always leave a trail of wet moisture If you are finding your floor too wet after use you may need...

Page 17: ...possible uses for the multi purpose steamer divided into recommended steam intensity settings These are only a guideline for using your steamer you will likely discover a wide variety of other uses a...

Page 18: ...thoroughly before reuse If the steam unit is damaged contact the Customer Service helpline Care of your microfibre cleaning pads Wash pads in warm water no more than 40 degrees Wash separately Do not...

Page 19: ...and so this will have to be disassembled carefully 3 Trouble converting from steam mop to handheld 3 Disassemble the handle by pushing in the small black button on the side of the handle connector th...

Page 20: ...be pressed to emit steam When the cleaner is being used as a mop the mop has to be reclined to emit steam 5 The attachment is not fitted correctly 5 All the attachments including the mop head fit in...

Page 21: ...ot the first time the product has been used 2 Discontinue use if problem persists and contact Customer Services using the details on the bottom of this page Parts have broken need replacing 1 An attac...

Page 22: ...inal proof of purchase The product must be installed and used in accordance with the instructions contained in this instruction guide and any other instructions for use which has been supplied It must...

Page 23: ...to make sure the success of these schemes and for the protection of the environment For your nearest disposal facility visit www recycle more co uk or ask in store for details We reserve the right du...

Page 24: ...lon Crevice brush Mop head Microfibre pads Cooling mat Measuring jug Handle 24 Spare parts The following spare parts are available to purchase online or by calling Product Care Visit us at www product...

Page 25: ...Check that the voltage marked on the product corresponds with your supply voltage This product is fitted with a 13A plug complying with BS1363 If this plug is unsuitable or needs to be replaced pleas...

Page 26: ...ed to the terminal which is marked with the letter E or by the earth symbol or coloured GREEN or GREEN YELLOW The BLUE wire is the NEUTRAL and must be connected to the terminal marked with the letter...

Page 27: ...Model number A21SM3001 R3a...

Reviews: