PROBOIL.2X user & installation guide v1e-2
19
9)
Remove the inlet meshed filter seal
(H)
from
the boiler inlet
(B)
or inlet adaptor
(G)
, rinse
the washer in cold water, and use a
toothbrush to clean any debris from it. If
meshed seal
(H)
is compressed inside inlet
(B)
or adaptor
(G)
then use a cocktail stick (or
similar) to remove it.
9.
Whilst taking care lift the PROBOIL.2X
(A)
unit out from the base unit and place it on the countertop.
10.
Tip the boiler upside down so the boilers
centre outlet
(C)
is over the sink, you must
empty the boiler as much as possible of water
and any debris, tip the boiler back and forth to
hear how much water remains inside if you
are unsure.
You can empty the boiler faster from the outlet
(C)
by
depressing the centre of the check valve insert found in the
boiler inlet
(B)
whilst the boiler is upside down.
11.
Use only a non-aggressive infant sterilising
solution (for example “Milton” concentrate).
Always read the label regarding the dilution
The total Proboil tank volume is 2.1
litres
so for a 0.6% v/v Milton concentrate
liquid we suggest you require a maximum of
13ml of concentrate.
Carefully measure out the sterilising solution
then tip the required amount of the solution
into the centre boiler outlet.
12.
Reconnect all the removed parts from the
boiler in the reverse order listed above.
(
do not use a spanner or overtighten
connectors G or J
)
13.
Turn on the 98°C tap handle on slowly, keep the handle on until you see water exit the spout of the tap then
turn it off immediately.
14.
Press and hold the
⏻
key for 1.5 seconds to activate, this will turn the boiler back on from “standby” mode
15.
Use the
+
and
-
key to change the target temperature on screen.
Change the pre-set water
target temperature to 98°C