PROBOIL 2 to PROBOIL.2X Upgrade Installation Guide v1b 

 

7)

 

Check the end of blue pipe 

(E)

 for signs of wear, if needed 

cut the worn section of the end of the pipe using a sharp 
Stanley knife or similar. 

 

8)

 

Push the ¼” blue flexible pipe 

(E)

 fully and firmly into the ¼” 

x ¼” pushfit connector 

(F)

 

 

 

9)

 

Firmly and fully push the silicone rubber outlet tube 

(K)

 over 

the red boiler outlet 

(J)

 
The silicone outlet tube 

(K) 

must: 

 
a)

 

Not

 be excessively long, creating a “dead leg”. 

b)

 

Not

 be too short (pipe is stretched). 

c)

 

Not 

be twisted or kinked when attached (creating a 

blockage). 

 
 

 

10)

 

Your boiler is now plumbed to the tap and the filter, plug the power cord into the mains outlet 

but do not 

switch on the mains power outlet at this time.

 

11)

 

Now turn on (open) fully the 98°C water handle. Water will now begin to purge air though the entire system. 

 

 During the purging of air it is normal for the tap to spit, continue until the stream from the centre channel 

of the tap aerator is continuous. Depending on the incoming water pressure it will take apx. 2-3 minutes to fill the 
tank and purge the air. 
 
12)

 

Now turn off (close) fully the 98°C water handle. 

 

 

 

Summary of Contents for Pronteau PROBOIL2

Page 1: ...www proboil co uk See top of boiler unit for contact details Please read these instructions carefully before installation We have a policy of continued product and quality development and improvement...

Page 2: ...proboil2x boilers like for like if any modifications are to be made please refer to the complete user and installer guide supplied originally with the product WARNING All surfaces especially those mad...

Page 3: ...place any water connections directly near or above electrical appliances or connections WARNING This appliance is not intended to be operated by means of an external time or separate remote control s...

Page 4: ...bols are used to highlight key points or safety considerations An information point or tip for installation or usage A service maintenance or care consideration A technical or safety consideration or...

Page 5: ...uding non return valve 1 B2 15mm olive B3 15mm nut B4 15mm pipe B5 15mm isolation valve B6 Domestic hot flexible hose excluding non return valve C1 Cold out to filter boiler flexible hose including se...

Page 6: ...nit Drain fully into a suitable container or sink 6 Once drained close the unit and place the boiler to one side EITHER Bypass the existing Proboil 2 black tundish assembly This is the preferred optio...

Page 7: ...cription Drawing A PROBOIL 2X boiler unit B male boiler inlet with internal check valve C 3 8 male boiler outlet D mains power cable E flexible blue inlet pipe F x inlet pushfit connector G blue Inlet...

Page 8: ...wingnut inlet connector with integral internal flat rubber seal G hand tight do not use a spanner or overtighten on to the boiler inlet male B 3 Check that the red 3 8 x 8mm boiler outlet connector J...

Page 9: ...be too short pipe is stretched c Not be twisted or kinked when attached creating a blockage 10 Your boiler is now plumbed to the tap and the filter plug the power cord into the mains outlet but do not...

Page 10: ...he flushing period check all connections made during the installation carefully for leaks 2 After the flushing period is completed turn off close fully the 98 C water handle 3 Press and hold the key o...

Reviews: