E-PGM+ / E-GANG4/6 / E-PGM Serial User’s Manual
4. Connection of Handler
41
4.2
E-GANG4 Handler Connections
The software and firmware for the E-PGM+, E-GANG4/6 and E-PGM Serial are available for
download from ABOV’s website (
Built-in internal isolator circuit
Used the handler power +5V or +3.3V (Used target power)
START: Input pin, active low
GOOD/FAIL: Output pin, active low, indicate signals
#1 Marking
1 2 3 4 5 6 7 8 9 10 11 12
Pin No. Marking
Name
1
Blank
Not used
2
/F4
FAIL4
3
/G4
GOOD4
4
T_5V
Target Power
5
/START
START
6
T_GND
Target GND
7
/F3
FAIL3
8
/G3
GOOD3
9
/F2
FAIL2
10
/G2
GOOD2
11
/F1
FAIL1
12
/G1
GOOD1
E-GANG4
Programmer
/START
/F1
/G1
T_5V
T_GND
Handler
6
5
11
12
4
Common
+5V
(+3.3V)
/F4
/G4
2
3
FAIL1
GOOD1
FAIL4
GOOD4
VCC
GND
FA
IL
4
G
O
O
D
4
T
_
5
V
S
T
A
R
T
T
_
G
N
D
FA
IL
3
G
O
O
D
3
FA
IL
2
G
O
O
D
2
FA
IL
1
G
O
O
D
1
L
R
TOP
Handler Interface Cable
(Active Low)
300mm
Length
START