background image

Add: 

1501 Industrial Way N, Toms River, NJ 08755   

Phone:

 866-222-8866   

E-mail: 

info@abovealllighting.com

 

Web:

 www.AboveAllLighting.com ©2016 ABOVE ALL Lighting, Inc. All rights reserved

3

MT LED AREA LIGHT / FLOOD LIGHT 

Instructions Manual

1.  Remove Screws A (2) and open the SF cover.  The removed Screws A (2) and SF cover will be used later.

2.  Remove Bolt B (M12) in the center of Slip Fitter and set apart the SF Arm A an B. Thread the luminaire cord through 

the SF Arm B. 

3.  Attach the SF Arm B to the luminaire using Crosshead Screw C, Spring and Flat Washer (6). Make sure the Gasket is 

between luminaire and Arm.  

4.  Thread the luminaire cord through the SF Arm A. Adjust the two SF Arms in desired angle then fasten the Bolt B (M12) 

again. Make sure the luminaire cord do not get pinched between two SF Arms.

5.  Reinstall the SF Cover with Screws A (2).

6.  Make wire connections between luminaire and supply wires in a pole or tenon with appropriate waterproof connectors 

and squeeze all the wires in the pole or tenon.

7.  Loosen Set Screw (4) on SF Arm. Slip the luminaire over a pole or tenon then tighten the Set Screws (4) to secure the 

luminarie.

SLIP FITTER MOUNT (SF) 

Crosshead Screw C, Spring and Flat Washer (6)

Bolt B, Spring and Flat Washer 

Set Screw (4)

Luminaire

SF Arm A

Screw A (2)

SF Cover

Gasket

Pole

SF Arm B

Reviews: