Add:
1501 Industrial Way N, Toms River, NJ 08755
Phone:
866-222-8866
E-mail:
info@abovealllighting.com
Web:
www.AboveAllLighting.com ©2016 ABOVE ALL Lighting, Inc. All rights reserved
3
MT LED AREA LIGHT / FLOOD LIGHT
Instructions Manual
1. Remove Screws A (2) and open the SF cover. The removed Screws A (2) and SF cover will be used later.
2. Remove Bolt B (M12) in the center of Slip Fitter and set apart the SF Arm A an B. Thread the luminaire cord through
the SF Arm B.
3. Attach the SF Arm B to the luminaire using Crosshead Screw C, Spring and Flat Washer (6). Make sure the Gasket is
between luminaire and Arm.
4. Thread the luminaire cord through the SF Arm A. Adjust the two SF Arms in desired angle then fasten the Bolt B (M12)
again. Make sure the luminaire cord do not get pinched between two SF Arms.
5. Reinstall the SF Cover with Screws A (2).
6. Make wire connections between luminaire and supply wires in a pole or tenon with appropriate waterproof connectors
and squeeze all the wires in the pole or tenon.
7. Loosen Set Screw (4) on SF Arm. Slip the luminaire over a pole or tenon then tighten the Set Screws (4) to secure the
luminarie.
SLIP FITTER MOUNT (SF)
Crosshead Screw C, Spring and Flat Washer (6)
Bolt B, Spring and Flat Washer
Set Screw (4)
Luminaire
SF Arm A
Screw A (2)
SF Cover
Gasket
Pole
SF Arm B