background image

Cardo Production Wexford Ltd., Clonard Road, Wexford, Ireland 

Tel. +353 53 91 63 200 Fax +353 53 91 42335. www.cardo.com

Summary of Contents for Piranha S10/4W-50

Page 1: ...www cardo com ABS Piranha submersible grinder pump S10 PE125 01 2011 GB Installation Operating and Maintenance Instructions...

Page 2: ...f approval 3 Safety 3 2 1 Use of explosion proof pumps in explosive zones 3 2 2 Special conditions for safe use of S type explosion proof motors 3 3 Technical data 4 3 1 Nameplate 4 4 General design f...

Page 3: ...ns as to safety make certain to contact the manufacturer ABS 1 Use of explosion proof pumps in explosive zones Explosion proof submersible pumps may only be operated with the thermal sensing system co...

Page 4: ...locations and the Ex nameplate must be removed Standard nameplate Cardo Production Wexford Ltd Wexford Ireland www cardo com Typ Nr Sn xx xxxx UN IN Ph Hz P1 P2 1 min Cos NEMA IP68 Qmax Hmax Imp DN Hm...

Page 5: ...r chamber pressure test point 6 Stainless steel shaft 7 Lower bearing double row 8 Oil lubricated lip seal 9 Bearing housing 10 Volute 1 Cast iron lifting handle and steel shackle 2 Upper bearing sing...

Page 6: ...le terminal block 4 Moisture sensor Di 5 Oil chamber 6 Oil chamber drain plug pressure test point 7 Stainless steel lifting hoop 8 Upper bearing single row 9 Motor with thermal sensors 10 Stainless st...

Page 7: ...the pump is being taken out of service the oil should be changed before storage After storage the pump should be inspected for damage the oil level should be checked and the impeller checked to ensur...

Page 8: ...uit the pump performance 6 1 Installation example in concrete sump 1 Sump cover 1005 00 2 Venting line 3 Sump cover 4 Protective duct to the control panel for cable 5 Chain 6 Inflow line 7 Ball type f...

Page 9: ...elevant safety regulations as well as general good technical practice must be complied with ATTENTION For use in the open air the following VDE regulations apply Submersible pumps used outdoors must b...

Page 10: ...E70 2E Ex PE90 2E Ex PE110 2E Ex Piranha 60 Hz S10 4 S10 4 Ex S20 2 S20 2 Ex S26 2 S26 2 Ex PE25 2C Ex PE35 2C Ex PE45 2C Ex S10 4 S10 4 Ex S20 2 S20 2 Ex S30 2 S30 2 Ex PE28 2C Ex PE35 2C Ex PE45 2C...

Page 11: ...o the direction of rotation ATTENTION When viewed from above the direction of rotation is correct if the impeller rotates in a clockwise manner NOTE The start reaction is anti clockwise NOTE If a numb...

Page 12: ...well as good general technical pratices should be followed NOTE The maintenance instructions given here are not designed for do it yourself repairs as special technical knowledge is required 9 1 Gener...

Page 13: ...of water into the oil chamber or motor chamber after repair work that requires draining of the oil if the pump is being taken out of service the oil should be changed before storage 9 3 1 Instruction...

Page 14: ...ent blocks every six months in a single family home once a year In addition we recommend that a maintenance contract be taken out with a qualified company 9 7 Cleaning If the pump is used for transpor...

Page 15: ...ngs in control panel Check for impeller blockage If none of above a service inspection is required 1 Low head or flow Wrong direction of rotation Change rotation by interchanging two phases of the pow...

Page 16: ...re in conformity with the following standards or other normative documents as defined by Machinery Directive 006 4 EC EMC Directive 004 108 EC Low Voltage Directive 006 95 EC ATEX 94 9 EC Construction...

Page 17: ...SERVICE LOG Pump Type Serial No Date Hours of Opera tion Comments Sign...

Page 18: ...SERVICE LOG Date Hours of Opera tion Comments Sign...

Page 19: ...SERVICE LOG Date Hours of Operation Comments Sign...

Page 20: ...Cardo Production Wexford Ltd Clonard Road Wexford Ireland Tel 353 53 91 63 200 Fax 353 53 91 42335 www cardo com...

Reviews: