ENG
7
Fig.5 and Fig. 6: 6V/ 12V
LCD charging block diagram
Precautions and Operating Instructions
1) Precautions:
a. The supply voltage of the product is 220~240VAC; please make sure that the mains voltage meets the
specifications of the product before using;
b. The charger is suitable for 6V/12V regular and Gel batteries with 5Ah ~ 120Ah capacity;
c. Clamp the battery anode with the red clip of the output line, and clamp the cathode with the black clip; it will
report error if the polarity is reverse;
d. The working environment of the product is 0°C~40°C; do not use beyond this range of temperature;
e. Before charging the battery, in order to prevent the equipment connected to the battery from damage or
unnecessary influence, disconnect the battery and the equipment before charging the battery;
2) Operating instructions:
A. Connection and reverse polarity: select the battery to be charged, confirm the input voltage and then insert the
power plug, enter into the initialization interface as follows Fig. 7; clamp the red clip of the output side to the anode
of the battery, and clamp the black clip to the cathode; if the polarity is reverse, the red (Fault) LED flashes at 1Hz,
and LCD displays as shown in Fig. 8
Fig. 7 Fig. 8