background image

Absco Industries

Assembly Instruction Manual

ABSCO REGENT SHED

MODEL: 23221RK

2.26mW x 2.18mD x 1.96mH

Model: 23221RK

17/03/21

1.1

1  

 

 

DOWNLOAD

 

OUR APP FOR

ASSEMBLY

VIDEOS

LEAVE A REVIEW

Tell us about your experience and 

receive a $20 Coles Gift Card.

Visit

 

www.abscosheds.com.au/review

AU: 1800 029 70

1

NZ: 0800 466 444

admin@absco.com.au

www.abscosheds.com.au

CONCRETE SLAB

2360mm

2280m

m

When laying concrete slab, ensure there 
is a rebated edge 25mm deep around 
the perimeter. This will help water egress 
from the base of the shed.

For construction in non-cyclonic areas

Wind rating: N2 as per AS4055-2012.
If you require a higher wind rating please contact 
us: admin@absco.com.au or 1800 029 701

ABSCO INDUSTRIES

ASSEMBLY INSTRUCTION MANUAL

SHED MODEL: 23151GK 

21-11-2017  

      

CONCRETE SLAB

2360mm

1620mm

FRONT:   2.26m

SIDE:       1.52m

HEIGHT:  1.95m

We thank you for choosing an Australian made

shed. For further assistance please visit our detailed

instructional video library at

Http://www.abscosheds.com.au/watch-videos

At ABSCO Industries we are always looking to be

number ONE, so please let us know what you think

of our instructions. Feedback makes us better.

feedback@absco.com.au

CONCRETE 

REBATED EDGE

BOTTOM CHANNEL

CONCRETE SLAB

75mm WIDE REBATE

100mm

WHEN LAYING YOUR CONCRETE

SLAB, ENSURE THERE IS A

REBATED EDGE 25mm DEEP

AROUND THE PERIMETER

THIS WILL HELP WATER EGRESS

FROM THE BASE OF THE SHED

Absco Industries

Premier Shed Model: 23151GK

PAGE 01

Summary of Contents for REGENT 23221RK

Page 1: ... higher wind rating please contact us admin absco com au or 1800 029 701 ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL SHED MODEL 23151GK 21 11 2017 CONCRETE SLAB 2360mm 1620mm FRONT 2 26m SIDE 1 52m HEIGHT 1 95m We thank you for choosing an Australian made shed For further assistance please visit our detailed instructional video library at Http www abscosheds com au watch videos At ABSCO Industrie...

Page 2: ...face may result in misalignment of parts The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately illustrated on FINAL CONSTRUCTION page TOOLS REQUIRED SAFETY NOTES Some parts may have sharp edges It is advisable to wear gloves when handling these items and safety glasses if drilling holes Sensible shoes are highly recommended Do not erect your shed in windy c...

Page 3: ...QTY QTY 2 3 2 2 6 1 1785mm X 773mm 30A STEEL SHEET STEEL SHEET 1785mm X 773mm 31A STEEL SHEET 1785mm X 731mm 32A STEEL SHEET 1725mm X 773mm B 97BL RIDGE BEAM L 1152mm STEEL SHEET 1170mm X 773mm 48L 2 STEEL SHEET 1170mm X 773mm 48R STEEL SHEET 1170mm X 773mm 49A 2 GABLE L H L 1105mm 17L 2 GABLE R H L 1105 17R 2 13B BRACE L 350mm 1 97BR RIDGE BEAM L 1152mm 1 ZARSP 1 RIDGE BEAM JOINER L 450mm 17 7 No...

Page 4: ...ON PART No CHECK COMPONENT DESCRIPTION PART No CHECK QTY QTY 1 1 2 2 2 81HL CHANNEL L 1089 5mm 1 76AL CHANNEL L 1126 5mm 54CL CHANNEL L 1126 5mm 1 76BL CHANNEL L 1126 5mm 81DL CHANNEL L 1126 5mm 59BL CHANNEL L 1089 5mm 78BL CHANNEL L 1126 5mm 1 1 2 2 2 81HR CHANNEL L 1089 5mm 1 76AR CHANNEL L 1126 5mm 54CR CHANNEL L 1126 5mm 1 76BR CHANNEL L 1126 5mm 81DR CHANNEL L 1126 5mm 59BR CHANNEL L 1089 5mm...

Page 5: ...A JAMB L 1785mm 91A JAMB L 1120mm 90B JAMB L 788mm 1 89B JAMB L 1785mm 1 86B LIP TRIM L 1170mm CSJ 12 CHANNEL JOINER L 200mm 7 9 10 DOOR PADBOLT HASP 1 1 SELF TAPPING SCREWS PACKET CONTAINING 220 1 DOOR PADBOLT FAST006 3 16 COUNTERSUNK SCREWS NUTS 6 3 2 x 8mm BLIND POP RIVETS 6 PSTKSGL SINGLE DOOR FITTINGS PACK PACK 6P SCREW PACK 6 PACK 6P SCREW PACK 6 1 PHILLIPS DRIVER BIT 3mm DRILL BIT DRILL FAS...

Page 6: ...e channel along the sheets until each end is neatly flush If you need to remove channels from the panels slide it off from the side Channel locks the shed panel into position without the need for screws FASTENING SYMBOLS Secure channel to sheeting by SNAPTiTE fastening method Join components together with one screw at this location only as some channels have extra holes that are not required for t...

Page 7: ...f the channel where the JOIN text is marked Push down one side of the CSJ until you hear a click Step 3 Join the second channel to the CSJ by positioning the JOIN of the channel at the centre of the CSJ on an angle Push the CSJ into the channel until you hear a click Finished Channel The joined channels should now look like the picture with the CSJ positioned equally inside of the joined channels ...

Page 8: ...ll holes where CSJ joining channel covers them Join together 24 x channel sections using 12 x channel joiners Part CSJ 2 X 78BR 2253mm 88 7 1 x 81D 2 x 78B 1 x 54C 1 x 76A 2 x 59B 2 x 81H 2179mm 85 8 59BR 81HL 81HR 59BL 76AR 76AL 54CL 54CR 78BR 78BL 81DL 81DR 1 X 81DR 1 X 81DL 2 X 78BL 1 X 54CR 1 X 54CL 1 X 76AR 1 X 76AL 2 X 59BR 2 X 59BL 2 X 81HR 2 X 81HL 1 x 76B 76BR 76BL 1 X 76BR 1 X 76BL 2 X 8...

Page 9: ...when the beams are in position Step 2 Use the ZARSP to connect at the centre of the two ridge beams Be sure it is pushed in fully Step 3 Turn over the ridge beam Measure 250mm from the middle along the centre of one ridge beam mark spacings of 50mm Fasten with a Tek screw at each marking Repeat to the other side of the ridge beam assembly TIP Predrilling each hole with the 3mm drill bit makes it e...

Page 10: ...mbly Instruction Manual ABSCO REGENT SHED MODEL 23221RK 2 26mW x 2 18mD x 1 96mH Model 23221RK 17 03 21 1 1 10 PRE ASSEMBLY OF SPLICED RIDGE BEAM 1x 97BL 1x 97BR 1x 97B 2253mm Overall length ZARSP 225mm 97BL 97BR 16mm 16mm ...

Page 11: ...ly Instruction Manual ABSCO REGENT SHED MODEL 23221RK 2 26mW x 2 18mD x 1 96mH Model 23221RK 17 03 21 1 1 11 OVERVIEW OF ROOF COMPONENTS OVERVIEW OF ROOF COMPONENTS 78B 48L 49A 48R 49A 48R 81C 86B 86B 81C 86B 14A 86B 97B 48L ...

Page 12: ...T SHED MODEL 23221RK 2 26mW x 2 18mD x 1 96mH Model 23221RK 17 03 21 1 1 12 OVERVIEW OF WALL COMPONENTS OVERVIEW OF WALL COMPONENTS 32A 31A 32A 32A 32A 32A 31A 13B 32A 30A 13B 31A 30A B 59B 17R 76A 59B 76B 17R 17L 81D 81H 54C 79B 89B 89A 90B 17L 81H 91A 22A ...

Page 13: ...sco Industries Assembly Instruction Manual ABSCO REGENT SHED MODEL 23221RK 2 26mW x 2 18mD x 1 96mH Model 23221RK 17 03 21 1 1 13 REAR PANEL ASSEMBLY 1x required 30A 31A 30A 76B 81D SNAPT TE i SNAPT TE i ...

Page 14: ...ruction Manual ABSCO REGENT SHED MODEL 23221RK 2 26mW x 2 18mD x 1 96mH Model 23221RK 17 03 21 1 1 14 ROOF PANEL ASSEMBLY 2x required Fit 81C to edge of sheet with pre punched holes 48L 49A 48R SNAPT TE i SNAPT TE i 86B 81C 86B 78B ...

Page 15: ...ries Assembly Instruction Manual ABSCO REGENT SHED MODEL 23221RK 2 26mW x 2 18mD x 1 96mH Model 23221RK 17 03 21 1 1 15 SIDE PANEL ASSEMBLY 2x required Small pan Small pan 32A 31A 32A 59B 81H SNAPT TE i SNAPT TE i ...

Page 16: ...sembly Instruction Manual ABSCO REGENT SHED MODEL 23221RK 2 26mW x 2 18mD x 1 96mH Model 23221RK 17 03 21 1 1 16 FRONT PANEL ASSEMBLY 1x required 89B 89A 32A 32A 76A 79B 54C 90B SNAPT TE i SNAPT TE i SNAPT TE i SNAPT TE i ...

Page 17: ... Model 23221RK 17 03 21 1 1 17 DOOR PANEL ASSEMBLY DOOR PANEL ASSEMBLY Vertical door channels are installed in the opposite orientation compared to the horizontal door channels Short flange of channel Long flange of channel SINGLE DOOR 58C 58C SNAP T TE i SNAP T TE i 12A B B 58B 58A D D D D 1x required ...

Page 18: ...ANEL NOTE Nuts and bolts are also supplied and may be used instead of rivets Use a 4mm drill bit to enlarge these holes in the jamb NOTE The holes to fasten the padbolt hasp are not pre punched to allow for proper alignment Position the hasp centrally over the padbolt shaft and drill 3mm holes and secure with screws 91A 91A DOOR PANEL ASSEMBLY B ...

Page 19: ...wn The top channels of each panel are pre punched for attaching roof sheeting The base channels are not pre punched Pre punched channel to match ridge beam holes Side wall channels fit into the notched rear wall channels Pre punched holes in roof panel to this side for connection to front and rear walls Orient panel so channel 78B goes into ridge beam Channel 81C this end 97B D D D D D D D D D D D...

Page 20: ...GS ALL WALL PANELS BY 37mm 13A Secure ridge beam to gable sections with two screws at each end Secure each roof panel with one screw in each corner only at this stage After attaching both roof panels to walls as shown above fit one regent brace to the ridge beam and front wall as shown You will have to remove and replace existing screws at fixing locations Repeat this procedure for the rear wall r...

Page 21: ...e into the wall sheet Drill a 10mm hole into the concrete Bolt and Nut M10 4 6 S Steel Angle 35 x 35 x 3 M10 Dynabolt Denotes hot dip galvanised finish Wall Sheet Slab 14A Bend the top and bottom flanges as shown then hook the bottom flanges under the top channel and screw top to the ridge beam with two screws ANCHORING OF SHED Location of 12 concrete anchors 700 700 700 700 700 700 1000 1000 50 5...

Page 22: ...the installation contractor Scaling of drawings shall not be undertaken 7 G Prior to commencing works on site the contractor shall verify the position of all services in the area to ensure that the construction does not interfere with any of those services 8 G During installation on site the shed structures shall be maintained in a stable condition with no part becoming overstressed or permanently...

Page 23: ...evant provisions of AS1562 Steelwork 1 F The supporting slab foundation for the garden shed shall be of a minimum size indicated on the installation manual The top surface of the formed slab shall be level and free of any irregularities which would inhibit the installation of the shed 2 F The structural engineering design for the supporting slab foundation shall be undertaken by a suitably qualifi...

Page 24: ...barrows garden tools etc Storage items that might be adversely affected by any of the above conditions may require additional protection such as being sealed or covered by plastic sheets and or stacked above the concrete floor on timber slats Waterproof sealants may be used to offer further protection where required around joins and screw fixings as can rubber door seals and other products which a...

Page 25: ...s of claiming warranty To make a claim under the warranty within the warranty period you will need to contact the manufacturer directly by phone or email Contact Number 1800 029 701 Contact Email admin absco com au You will be required to produce proof of purchase this is at discretion of the manufacturer at the time of the claim The manufacturer bears the cost of replacing the products or spare p...

Page 26: ... equipment and should not be used for articles that may be prone to damage if they come into contact with moisture 3 Major Defects If the manufacturer is satisfied that the defect is a major defect the purchase price may be refunded in lieu of providing a replacement product or repairing the product This warranty is provided in addition to other rights and remedies you have under law Our goods come...