6  

 

 

OVERVIEW OF ROOF COMPONENTS

OVERVIEW OF ROOF COMPONENTS

50L

50L

50R

50R

85B

14A

85B

97C

78C

81E

85B

85B

81E

Summary of Contents for 15141RK

Page 1: ...lease contact us admin absco com au or 1800 029 701 ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL SHED MODEL 23151GK 21 11 2017 CONCRETE SLAB 2360mm 1620mm FRONT 2 26m SIDE 1 52m HEIGHT 1 95m We thank you for choosing an Australian made shed For further assistance please visit our detailed instructional video library at Http www abscosheds com au watch videos At ABSCO Industries we are always looki...

Page 2: ... the shed must be level An uneven surface may result in misalignment of parts The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately illustrated on FINAL CONSTRUCTION page TOOLS REQUIRED SAFETY NOTES Some parts may have sharp edges It is advisable to wear gloves when handling these items and safety glasses if drilling holes Sensible shoes are highly recommen...

Page 3: ...3mm 30A STEEL SHEET STEEL SHEET 1785mm X 731mm 32A STEEL SHEET 1725mm X 773mm B 81I CHANNEL L 1439 59C CHANNEL L 1439 STEEL SHEET 795mm X 773mm 50L 2 STEEL SHEET 795mm X 773mm 50R 2 GABLE L H L 735mm 18L 2 GABLE R H L 735mm 18R 1 75A CHANNEL L 1513mm 53B CHANNEL L 1513mm 1 75C CHANNEL L 1513mm 1 CHANNEL L 1513mm 81E 78C CHANNEL L 1513 97C RIDGE BEAM L 1513 STEEL SHEET 1785mm X 731mm 33A 1 STEEL SH...

Page 4: ...INGES L 1725mm 58B CHANNEL L 1725mm 58C CHANNEL L 773mm 89A JAMB L 1785mm 91A JAMB L 1120mm 90C JAMB L 783mm 1 89B JAMB L 1785mm 1 85B LIP TRIM L 795mm SELF TAPPING SCREWS 20mm 6 DOOR PADBOLT HASP 1 1 SELF TAPPING SCREWS PACKET CONTAINING 220 1 DOOR PADBOLT FAST006 3 16 COUNTERSUNK SCREWS NUTS 6 3 2 x 8mm BLIND POP RIVETS 6 PSTKSGL SINGLE DOOR FITTINGS PACK PACK 6P SCREW PACK 6 PACK 6P SCREW PACK ...

Page 5: ...e channel along the sheets until each end is neatly flush If you need to remove channels from the panels slide it off from the side Channel locks the shed panel into position without the need for screws FASTENING SYMBOLS Secure channel to sheeting by SNAPTiTE fastening method Join components together with one screw at this location only as some channels have extra holes that are not required for t...

Page 6: ...ssembly Instruction Manual ABSCO REGENT SHED MODEL 15141RK 1 52mW x 1 44mD x 1 96mH Model 15141RK 14 09 18 1 1 6 OVERVIEW OF ROOF COMPONENTS OVERVIEW OF ROOF COMPONENTS 50L 50L 50R 50R 85B 14A 85B 97C 78C 81E 85B 85B 81E ...

Page 7: ...ABSCO REGENT SHED MODEL 15141RK 1 52mW x 1 44mD x 1 96mH Model 15141RK 14 09 18 1 1 7 OVERVIEW OF WALL COMPONENTS OVERVIEW OF WALL COMPONENTS 33A 32A 30A 30A 32A 32A 34A B 53B 79C 89B 89A 81I 90C 80A 81I 81F 59C 18L 75A 18R 18L 18R 59C 22A 91A 75C ...

Page 8: ...Absco Industries Assembly Instruction Manual ABSCO REGENT SHED MODEL 15141RK 1 52mW x 1 44mD x 1 96mH Model 15141RK 14 09 18 1 1 8 REAR PANEL ASSEMBLY 1x required 30A 30A 75C 81F SNAPT TE i SNAPT TE i ...

Page 9: ...nstruction Manual ABSCO REGENT SHED MODEL 15141RK 1 52mW x 1 44mD x 1 96mH Model 15141RK 14 09 18 1 1 9 ROOF PANEL ASSEMBLY 2x required Fit 81E to edge of sheet with pre punched holes 50L 50R SNAPT TE i 78C 85B 81E 85B SNAPT TE i ...

Page 10: ...dustries Assembly Instruction Manual ABSCO REGENT SHED MODEL 15141RK 1 52mW x 1 44mD x 1 96mH Model 15141RK 14 09 18 1 1 10 RIGHT SIDE PANEL ASSEMBLY 1x required Small pan 32A 32A SNAPT TE i SNAPT TE i 59C 81I ...

Page 11: ...ustries Assembly Instruction Manual ABSCO REGENT SHED MODEL 15141RK 1 52mW x 1 44mD x 1 96mH Model 15141RK 14 09 18 1 1 11 LEFT SIDE PANEL ASSEMBLY 1x required SNAPT TE i SNAPT TE i 59C 81I 32A 33A 80A Small pan ...

Page 12: ...Industries Assembly Instruction Manual ABSCO REGENT SHED MODEL 15141RK 1 52mW x 1 44mD x 1 96mH Model 15141RK 14 09 18 1 1 12 FRONT PANEL ASSEMBLY 1x required SNAPT TE i SNAPT TE i 34A 89A 53B 75A 79C 89B 90C ...

Page 13: ... Model 15141RK 14 09 18 1 1 13 DOOR PANEL ASSEMBLY DOOR PANEL ASSEMBLY Vertical door channels are installed in the opposite orientation compared to the horizontal door channels Short flange of channel Long flange of channel SINGLE DOOR 58C 58C SNAP T TE i SNAP T TE i 12A B B 58B 58A D D D D 1x required ...

Page 14: ...ANEL NOTE Nuts and bolts are also supplied and may be used instead of rivets Use a 4mm drill bit to enlarge these holes in the jamb NOTE The holes to fasten the padbolt hasp are not pre punched to allow for proper alignment Position the hasp centrally over the padbolt shaft and drill 3mm holes and secure with screws 91A 91A DOOR PANEL ASSEMBLY B ...

Page 15: ...or attaching roof sheeting The base channels are not pre punched Pre punched channel to match ridge beam holes Side wall channels fit into the notched rear wall channels Pre punched holes in roof panel to this side for connection to front and rear walls Orient panel so channel 78C goes into ridge beam Channel 81E this end 97C 33A 80A 89B CONNECT DOOR MULLION SECTIONS WITH SIX 20mm SCREWS REPLACE P...

Page 16: ...41RK 1 52mW x 1 44mD x 1 96mH Model 15141RK 14 09 18 1 1 16 INSIDE VIEW OF FIXING OUTSIDE VIEW 37mm ROOR OVERHANGS ALL WALL PANELS BY 37mm Secure ridge beam to gable sections with two screws at each end Secure each roof panel with one screw in each corner only at this stage ...

Page 17: ... 10mm hole into the wall sheet Drill a 10mm hole into the concrete Bolt and Nut M10 4 6 S Steel Angle 35 x 35 x 3 M10 Dynabolt Denotes hot dip galvanised finish Wall Sheet Slab 14A Bend the top and bottom flanges as shown then hook the bottom flanges under the top channel and screw top to the ridge beam with two screws ANCHORING OF SHED 50 700 Location of 8 concrete anchors 50 50 50 700 700 700 70...

Page 18: ...the installation contractor Scaling of drawings shall not be undertaken 7 G Prior to commencing works on site the contractor shall verify the position of all services in the area to ensure that the construction does not interfere with any of those services 8 G During installation on site the shed structures shall be maintained in a stable condition with no part becoming overstressed or permanently...

Page 19: ...evant provisions of AS1562 Steelwork 1 F The supporting slab foundation for the garden shed shall be of a minimum size indicated on the installation manual The top surface of the formed slab shall be level and free of any irregularities which would inhibit the installation of the shed 2 F The structural engineering design for the supporting slab foundation shall be undertaken by a suitably qualifi...

Page 20: ...barrows garden tools etc Storage items that might be adversely affected by any of the above conditions may require additional protection such as being sealed or covered by plastic sheets and or stacked above the concrete floor on timber slats Waterproof sealants may be used to offer further protection where required around joins and screw fixings as can rubber door seals and other products which a...

Page 21: ...ss of claiming warranty To make a claim under the warranty within the warranty period you will need to contact the manufacturer directly by phone or email Contact Number 1800 029 701 Contact Email admin absco com au You will be required to produce proof of purchase this is at discretion of the manufacturer at the time of the claim The manufacturer bears the cost of replacing the products or spare ...

Page 22: ... prone to damage if they come into contact with moisture We recommend you use a waterproof sealant to fill any gaps or joins in order to minimise the risk of water entering 3 Major Defects If the manufacturer is satisfied that the defect is a major defect the purchase price may be refunded in lieu of providing a replacement product or repairing the product This warranty is provided in addition to ...