16. END THE CHARGING PROCESS
During charging, the charging process can be
terminated as follows:
§
Pass the RFID card past the wallbox receiver to end
the charging process prematurely. When the vehicle
is unlocked, you can disconnect the charging plug.
§
The vehicle battery is fully charged and the vehicle
ends the charging process. When the vehicle is
unlocked, you can disconnect the charging plug.
17. ERROR DESCRIPTION
ERROR
CAUSE
MEASURE
OVERLOAD
Input voltage is too high.
If the input voltage exceeds 460V AC, the wallbox
detects overvoltage and switches off. Have the
installation checked.
UNDERVOLTAGE
Input voltage is too low.
If the input voltage is below 300V AC, the wallbox
detects undervoltage and switches off. Have the
installation checked.
OVERHEAT
The internal temperature of the
wallbox is above 85°C.
Make sure that the ambient temperature is
below 60°C. If the internal temperature exceeds
85°C, the wallbox will switch off. Avoid direct
sunlight.
LEAKAGE CURRENT
EXCEEDS THE
LIMIT
The earthing is poor or the
CC/CP connection of the
charging plug is incorrect.
The wallbox switches off. Have your installation
checked.
OVERCURRENT
The input current is too high.
The wallbox switches off at input currents above
18A. Have your installation and cables checked
for damage.