LED RED
DESCRIPTION
DECLARATION
Standby
Sleep mode.
Normal connection
Charging cable is connected to the vehicle.
Charging
Battery is charging.
Charging
completed
Battery is fully charged.
Failed self-test
The control box cannot establish communication with the vehicle. Check that the
connectors are correctly seated and check for dirt in the de-energised state. If the fault
cannot be rectified, send the charging cable to the manufacturer for inspection.
Low voltage
The supply voltage is outside the tolerance range. Check the mains voltage.
Over voltage
The supply voltage is outside the tolerance range. Check the mains voltage.
Leakage current
The control box detects a fault current. Stop charging, disconnect the charging cable
from the vehicle and check the wiring / vehicle. Visit a specialist workshop.
Over current
The charging current is above the maximum value. Stop charging and check the
compatibility of the charging cable.
Charger
overheated
The control box is overheated. This can be caused, for example, by direct sunlight during
the charging process. The charging process is interrupted. After cooling down, the
charging process starts automatically.
PE error
The control box detects a fault in the PE line. Check mains socket / mains connection.
= ON
= FLASH
ERROR
The charging cable has several monitoring functions that are indicated by the LEDs.
=
OFF
LED
GREEN
LED
BLUE
2x
3x
4x
5x
6x
7x
Deutsch .
English
. Français . Español . Italiano