SECTION 4 MAINTENANCE AND SERVICE
• Symptom (Warning Message): OZONE CELL PRESSURE TOO LOW
Please make sure there are no restrictions on the oxygen line coming
to the ozone generator and that the flow is only adjusted on the ozone
line after the ozone generator to maintain correct working pressure,
if the pressure is too low due to incorrectly set pressure regulator or
failure of oxygen generators, please rectify the problem and the ozone
generator will continue operation.
• Syptom (Warning Message): OZONE CELL PRESSURE TOO HIGH
Please adjust oxygen pressure regulator to specified pressure and that
will rectify this problem and warning message.
• Symptom (Warning Message): OZONE CELL TEMPERATURE TOO
HIGH
Make sure that the ambient temperature in the installation room is be-
low 25 c, check that there is good unrestricted cooling airflow through
the ozone generator (not obstructed on either side of cooling grills).
please make sure that the cooling fan is working properly. in case of
the cooling fan failure, please contact technical support for further in-
structions
• Symptom (Warning Message): SUPPLY VOLTAGE TOO HIGH OR
TOO
LOW
Please make sure that the voltage supplied to the ozone generator as
spe/- 5% in order to correct the problem. if voltage supplied is
as specified and the problem persists, please contact our service de-
partment