19
SECTION 4 MAINTENANCE AND SERVICE
Symptom (Warning Message):
• INCORRECT REMOTE CONTROL VOLTAGE
Please make sure the voltage you have supplied to the re-
mote control (4-20 MA signal) is not higher than 10V.
• OZONE CELL CONTAMINATION.
The ozone sensor detected ozone cell contamination by wa-
ter or possibly some other conductive liquids. Please switch
the ozone generator off, locate and eliminate the source
of the contamination. While having power off run oxygen
through the ozone cell for several days to dry the liquid and/
or other contaminants out and then try to restart the ozone
generator.
• SYSTEM COMMUNICATION PROBLEM
If after several at-
tempts does not restart, please contact us technical support
• OZONE SENSOR PROBLEM
If after several attempts does not restart, please contact us
for technical support