Valve Positioner/Actuator/Controller, Field Rangeable
APD 3280
Control Input:
0-50 mV to 0-10 VDC, 0-1 mA to 0-20 mA, 4-20 mA
Position Feedback:
Potentiometer
Output:
8 A SPDT Relay with Neutral Position
O
Automatic or Manual Valve Control
O
Test/Manual Positioning Buttons
O
Input LoopTracker
®
LED
O
Relay Status LEDs
O
High Capacity Relay Contacts
O
One Minute Field Setup
O
Removable Plugs for Faster Installation
O
Input/Power Isolation
Applications
Description
The APD 3280 controls the position of a valve or linear actuator
by comparing a DC input (control signal) to that of a position
feedback potentiometer or slidewire.
An SPDT relay provides bi-directional (open-close) signals to
drive a motor to open or close a valve. A bi-color LED indicates
the Open/Close relay contact status.
When the valve position, as indicated by the feedback poten-
tiometer, becomes equal to the position as represented by the
control input, the relay will go to the neutral position and the
motor will halt. A multi-turn deadband control allows precise
tuning of the motor response to eliminate hunting or oscillation.
Heavy-duty relay contacts allow the module to directly control
high capacity loads as long as the switching current with within
the limits shown at left.
Auto/Manual Switch
An Auto/Manual switch allows either closed-loop automatic
valve position control or manual positioning via the Open/
Close buttons.
The manual mode is useful for troubleshooting, calibration,
system testing or as a manual bypass.
LoopTracker
A green LoopTracker LED varies in intensity with changes in
the control input signal. Monitoring this LED can provide a
quick visual picture of your process at all times and save time
during initial startup and/or troubleshooting.
Models are field rangeable. Switches can pre-set to your
specifications. See range table on other side.
Any full range feedback potentiometer or slidewire from
0-100
Ω
to 0-100 k
Ω
can be used, no need to specify range.
Order APD 3280 D for operation on low voltage power.
Please Specify
Model
Control input range (if factory is to pre-set switches)
Options as required
How to Order
Removable Plugs
Dimensions
0.89" W x 4.62" H x 4.81" D
22.5 mm W x 117 mm H x 122 mm D
Height includes connectors
Control Input
Minimum Span
Maximum Span
Voltage:
0-50 mVDC
0-10 VDC
Current:
0-1 mADC
0-20 mADC
1 VDC maximum burden @ 20 mA
Control Input Impedance
Voltage:
250 k
Ω
min.
Current: 50
Ω
typical
Common Mode Rejection
100 dB minimum
Input Calibration
Multi-turn zero and span potentiometers
±10% of span adjustment range typical
Loop Power Supply
15 VDC ±10%, 25 mA max. to power external loads such as
loop powered transmitters, sensors, etc.
Feedback Potentiometer Range
Any full range potentiometer 0-100
Ω
to 0-100 k
Ω
Potentiometer excitation: 1.0 VDC nominal, 10 mA maximum
Manual Controls
Automatic/manual switch
Manual open and close buttons
LoopTracker
Variable brightness LEDs for input level and status
Relay Output
SPDT relay with neutral contact position
8 A max @ 240 VAC resistive load
An RC snubber is recommended for inductive loads
Deadband
12 turn potentiometer adjustable from 1 to 25% of span
Response Time
100 milliseconds nominal
Isolation
Power to input isolation
Housing and Connectors
IP 40, requires installation in panel or enclosure
For use in Pollution Degree 2 Environment
Mount vertically to a 35 mm DIN rail
Four 4-terminal removable connectors, 14 AWG max wire size
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.02% of span per °C stability
Power
85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum
D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum
Q
Valve Position Controller
Q
Linear Actuator Controller
Q
Damper Controller
Model
Description
Power
APD 3280
Field configurable valve
positioner for potentiometer
or slidewire feedback.
8 A max. SPDT relay output
60-265 VAC or
85-300 VDC
APD 3280 D
9-30 VDC or
10-32 VAC
Optional
—
add to end of model number
U
Conformal coating for moisture resistance
Accessory—order as separate line item
API BP4
Spare removable 4 terminal plug, black
Options and Accessories
8 A max Relay
Output with
Neutral Position
Potentiometer or
Slidewire Feedback
Input LoopTracker
LED
Adjustable Relay
Deadband
Zero and Span for
Input
Connect Sink or
Source mA Input
24 Switch Selectable
Input Ranges
Relay Status LED
Auto/Manual Switch
Manual Open/Close
Buttons
See API 3200 G or
APD 3200 for 4-20 mA
or Voltage Feedback
Switching Current (A)
Switching Voltage (V)
0
3 5 10
30 50 100 300 500
8
5
3
1
0.5
0.3
0.1
AC inductive load
(cos
f
= 0.4)
AC resistive
load
DC inductive load
(L/R = 7 ms)
DC resistive
load
© 11-19
api-usa.com
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
Fax: 800-949-7502
A
A
BSOLUTE
BSOLUTE
P
P
ROCESS
ROCESS
I
I
NSTRUMENTS
NSTRUMENTS
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
See Wiring
Diagrams on
Next Page
Universal Power
Quick Link:
api-usa.com/3280
Minute
Setup!
1
Free Factory
I/O Setup!
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
File E145968
85-265 VAC, 60-300 VDC
model only
Applications Link
api-usa.com/apps
Pb
Lead