background image

User Operation Guide

** For detail, updated Command Code and Application Software, please visit and download from 

www.abtussingapore.com

PRODUCT HIGHLIGHTS

Multi-Stage surge protection

Linear Filtering Technology

Front panel power status LEDs

External I/Os allow remote operation

** For detail, updated Command Code and Application Software, please visit and download from 

www.abtussingapore.com

Item

Description

1. POWER 

Main Power ON/OFF switch

2. CIRCUIT BREAKER

Max overall load capacity is 10 amp, this circuit breaker will trip should the combined
current drawn by all connected equipments exceed 10 amp.
Should this occurs, reduce the load so that they are within the range.
Reset can be done by simply pressing the reset button, however, please note that this is a
thermal trip supplementary protector. (*Cooling time is required before reset is allow)

3. SWTCHED AC OUTLET

Provide a power outlet from front panel with main power ON/OFF and when the system
is in and under normal power condition.

4. PROTECTION OK

LED is at solid green when system is under normal condition.
LED goes OFF when a extreme large surge occurs, all relays will open.

5. EXTREME VOLTAGE

LED is normally off, it will only turn solid red when unit received voltage that is out of
the range below (185VAC) or above (265VAC)
*System will only allow reset (OFF/ON main power switch) when the incoming voltage
is back within the safety range.

6. SEQUENCE START

Push to reset and begin an ON sequence

7. DELAY STATUS

LEDs, each LED provide the relay/delay status of the corresponding port.

8. SEQUENCE ON/OFF

ON/OFF of a sequence which allow outlets to be turn on one at a time with a delay time
(Variable and programmable) between each one.

9. LAMP ON/OFF

ON/OFF control for rear 12VDC (500mA) supply which allow any gooseneck lamp/LED
to be connected.

Front Panel View

1

2

3

4

5

6

7

8

9

8 switched outlets (rear) and one pass through
un-switched outlet (front)

12VDC supply (BNC) allow any gooseneck lamp or LEDs

    that provides a cool running source for the rack

1

2

3

4

Item

Description

1. LAMP 

BNC 12VDC (500mA) gooseneck lamp/LED

2. LED - START SEQ- GND 

External control and status for Start Sequence

3. DELAY 1 to DELAY 8 

AC outlet with delays and sequence based on programmed timing (1~60 Sec)

4. AC AC220~240 50/60Hz 

AC Input socket, AC220~240 50/60Hz

Communication Parameter

RS-232 Command Code

Description

Setting

Baud Rate : 

9600bps

Data Length :  8 bits

Parity : 

Non Parity

Stop Bit : 

One stop bit

X On/Off : 

None

RS-232 connection

Pin

Function

 1       Tx 

Transmit data

 2       Rx 

Receive data

 3       GND 

Ground

Tx - Rx - GND

Item

Description

Command code (Hex)

1.

Enter Setting Mode 

Send

53 45 54 53 07 50 57 52 44 41 30 39 43

Return

52 45 54 53 07 50 57 52 44 41 30 39 43

2.

Set Relay 01 ON (Hex 01) Delay 01 sec 

Send

53 45 54 53 04 44 4C 01 01

Return

52 45 54 53 04 44 4C 01 01

3.

Set Relay 02 ON (Hex 02) Delay 02 sec 

Send

53 45 54 53 04 44 4C 02 02

Return

52 45 54 53 04 44 4C 02 02

4.

Set Relay 03 ON (Hex 03) Delay 03 sec

Send

53 45 54 53 04 44 4C 03 03

Return

52 45 54 53 04 44 4C 03 03

5.

Set Relay 04 ON (Hex 04) Delay 04 sec 

Send

53 45 54 53 04 44 4C 04 04

Return

52 45 54 53 04 44 4C 04 04

6.

Set Relay 05 ON (Hex 05) Delay 05 sec 

Send

53 45 54 53 04 44 4C 05 05

Return

52 45 54 53 04 44 4C 05 05

7.

Set Relay 06 ON (Hex 06) Delay 06 sec 

Send

53 45 54 53 04 44 4C 06 06

Return

52 45 54 53 04 44 4C 06 06

8.

Set Relay 07 ON (Hex 07) Delay 07 sec 

Send

53 45 54 53 04 44 4C 07 07

Return

52 45 54 53 04 44 4C 07 07

9.

Set Relay 08 ON (Hex 08) Delay 08 sec 

Send

53 45 54 53 04 44 4C 08 08

Return

52 45 54 53 04 44 4C 08 08

10.

Set Relay 08 ON (Hex 08) Delay 10 sec (Hex 0A) 

Send

53 45 54 53 04 44 4C 08 0A

Return

52 45 54 53 04 44 4C 08 0A

11. 

Set Relay 08 OFF (Hex 10) Delay 01 sec 

Send

53 45 54 53 04 44 4C 10 01

Return

52 45 54 53 04 44 4C 10 01

12.

Set Relay 07 OFF (Hex 0F) Delay 02 sec 

Send

53 45 54 53 04 44 4C 0F 02

Return

52 45 54 53 04 44 4C 0F 02

13.

Set Relay 06 OFF (Hex 0E) Delay 03 sec 

Send

53 45 54 53 04 44 4C 0E 03

Return

52 45 54 53 04 44 4C 0E 03

14.

Set Relay 05 OFF (Hex 0D) Delay 04 sec 

Send

53 45 54 53 04 44 4C 0D 04

Return

52 45 54 53 04 44 4C 0D 04

15.

Set Relay 04 OFF (Hex 0C) Delay 05 sec 

Send

53 45 54 53 04 44 4C 0C 05

Return

52 45 54 53 04 44 4C 0C 05

16.

Set Relay 03 OFF (Hex 0B) Delay 06 sec 

Send

53 45 54 53 04 44 4C 0B 06

Return

52 45 54 53 04 44 4C 0B 06

17.

Set Relay 02 OFF (Hex 0A) Delay 07 sec 

Send

53 45 54 53 04 44 4C 0A 07

Return

52 45 54 53 04 44 4C 0A 07

18.

Set Relay 01 OFF (Hex 09) Delay 08 sec 

Send

53 45 54 53 04 44 4C 09 08

Return

52 45 54 53 04 44 4C 09 08

19.

Set Relay 01 OFF (Hex 09) Delay 10 sec (Hex 0A)

Send

53 45 54 53 04 44 4C 09 0A

Return

52 45 54 53 04 44 4C 09 0A

20.

Exit (Setting Mode) 

Send

53 45 54 53 06 49 53 50 4F 4B 21

Return

53 45 54 53 06 49 53 50 4F 4B 21