background image

10 Revised 

10/2014 

will save time since the system will not have to be unhooked.  
We have included the pictures and descriptions along with color 
coded tubing to make connecting the system simple. If unsure, 
feel free to contact us for assistance. Refer to Pre-installation 

section for help with quick connect fittings. 

Please Note:

 Pictures 

are for reference only, system variations may occur.  

Feed Water Line – RED 

 Connects from the inlet side of the first housing to the 
angle valve adapter.  

 

Tank Line – CLEAR 

Connects from the Tee-fitting (connected to membrane 
or UV filter depending on system configuration) to the 
ball valve on the tank. The tank valve is in the open 

position when the handle is in line with the tubing. 

Faucet (Good Water) Line – BLUE 

Connects from the outlet side of the post filter to the 
faucet shank. If using the compression fitting that 
comes with the faucet, slide the nut over the tube, 
followed by the ferrule, placing the insert into the end 
of the tube. Push the tube into the faucet shank and 

secure by tightening the line nut. (Refer to Figure 1) 

Drain (Waste Water) Line – YELLOW 

PRE-CONNECTED - Connects from the membrane to the drain 
saddle valve.   
 

 

©2014 Abundant Flow Water Systems, Inc. 

 11 

Example of Connected System 

(System may differ from the one shown) 

 

Optional Ice Maker Kit Installation 

You can use your Reverse Osmosis system to provide filtered 
water for your refrigerator ice or water machine using kits 
available on our website or by calling us at 785-735-9769. 
Find the line that leads to the faucet on the RO system.  Cut line 
with sharp knife or scissors.  Connect the T-connector to both 
ends of the line by pushing tubing into slip connectors firmly. 
 
Cut a short length of tubing to insert into T-connector T-off. Insert 
other end of this tubing into shut off valve fitting.  Connect tubing 
to other end of shut off valve and into ice machine or water 
machine.  Lengths over 15’-20’ will lose pressure so use shortest 
route possible. 

System Start Up: 

After all the connections have been made it is time to prepare the 
system for use. If the system has a UV filter, plug the wire coming 

Summary of Contents for Zoi DFK-Alpha

Page 1: ...return items without a RMA and contact us with details about the return will be responsible for return shipping regardless of warranty covered defects LIMITATIONS AND EXCLUSIONS Abundant Flow Water w...

Page 2: ...transformers clips check valves flow restrictors ball valves storage tanks faucets adapters drain valves filter housing wrenches tubing and accessories included in your original order What Does This W...

Page 3: ...s IN OUT Ultra Violet UV Filter Connects to UV Transformer Water can ow either direction depending on install Solid Blue with a stem on each end RO Membrane YELLOW BLACK Wastewater Line Clamps around...

Page 4: ...alve Defective Auto Shut Off Replace auto shut off valve Defective Flow Restrictor Replace flow restrictor Obstruction In Line Ensure valves open no kinks in lines Trace flow of water Tank Not Holding...

Page 5: ...not allowing water through replace the auto shut off valve 9 Ensure tank ball valve closed and check the flow of water after each of the inline filters Inline filters may include post filter pH filter...

Page 6: ...om fitting Turn feed water valve back on ensuring it is fully open before checking flow Repeat this process with each step until the problem is found 1 Check feed water line red connected to the inlet...

Page 7: ...recommended to 2014 Abundant Flow Water Systems Inc 1 Pre installation Preparation IMPORTANT Read through the entire instruction manual before beginning installation Abundant Flow Water is not respons...

Page 8: ...have room for everything and plan room for future filter changes 4 Familiarize yourself with the quick connect fittings Your system uses quick connect fittings There is a collet ring at the end of th...

Page 9: ...ousing some housings have 2 and screw the membrane housing cap back onto the housing 10 Push the tubing back into the fitting on the membrane cap 11 If the filters need changed now is a good time to d...

Page 10: ...ter Systems Inc 17 handle is at a 90 angle to the tubing when the handle is NOT parallel to the tubing 3 Open the faucet to release any remaining pressure 4 Unscrew the cap on the UV filter and carefu...

Page 11: ...hten until snug making sure to not over tighten which would cause the filter to crack or could strip out the threads 3 Now we will install the filter s in the order shown by the diagram on the back of...

Page 12: ...filter paying careful attention to the direction of flow as indicated on the filter and ensuring the new filter is installed in the same direction as the old filter Do this with each inline filter yo...

Page 13: ...rs in the housings have been changed it is time to change the inline filter s the post filter as well as the pH Mineral filter Alkaline filter if the system 2014 Abundant Flow Water Systems Inc 7 may...

Page 14: ...he waste water from your system down the drain Depending on where the saddle is located you may hear water running down the drain when the system is making water this is normal If the sound is annoyin...

Page 15: ...his flushes the system removing any preservatives from the membrane and cleaning off the filters 10 Repeat steps 8 9 at least once ensuring the system is flushed and ready to use 11 The system is now...

Page 16: ...the end of the tube Push the tube into the faucet shank and secure by tightening the line nut Refer to Figure 1 Drain Waste Water Line YELLOW PRE CONNECTED Connects from the membrane to the drain sad...

Reviews: