2. Tap the sensor with your hand. Tap it at
the strength where the sensor should
trigger an alarm.
The calibration mode LED flashes:
Once for a small vibration
Twice for a vibration that triggers an
alarm
Three times for a strong vibration
3. Adjust the potentiometer until the LED
flashes twice at every vibration in the
desired sensitivity range.
4. Remove jumper A if the sensor does not
register all vibrations in the desired sen-
sitivity range.
5. Remove jumper C when the sensor has
been set to the desired sensitivity. This
puts the detector into normal operating
mode.